Trouble shooting – Enviro C-11212 User Manual
Page 26
Trouble Shooting
Problem
Possible Cause
Solution
The main burner
does not ignite
when called for.
The gas valve may not be on.
• Check that the gas control knob is in the “ON” position.
Thermostat is not calling for
heat.
• Adjust the thermostat several degrees above ambient temperature.
Problem with gas valve.
• Use a DC voltmeter to measure the voltage across the TPTH and TP
terminals. Main operator voltage: Open circuit ≥ 325mV & Closed
circuit ≥ 100mV.
• If voltage is not present, check the control circuit for proper
operation.
• If proper control system voltage is present, replace the gas control.
Spark will not
light the pilot
after repeatedly
pressing the
spark ignitor.
Defective piezo ignitor.
• Check connections to ignitor.
• If ignitor connections are good but no spark, replace ignitor.
Broken spark electrode.
• Check for broken ceramic insulation, replace electrode if broken.
Misaligned spark electrode.
• If spark is not arcing from electrode to pilot, loosen the screws on the
pilot base, adjust, and tighten.
Pilot will not
remain lit.
Problem with thermocouple
circuit.
• Check for proper connection of the thermocouple to the rear of the
valve. If loose, fully tighten.
• Check pilot for full flame impingement around thermocouple. If flame
is too small, check gas pressure, adjust pilot rate screw, check pilot
head for damage.
• Check thermocouple voltage at valve. It must be greater than 5 mV.
If low, replace thermocouple.
Air in gas line (pilot dies while
knob is depressed).
• Bleed line.
• Check gas line pressure.
• Contact dealer.
Burners will not
remain lit.
Problem with thermopile
circuit.
• Check gas line pressure.
• Check for flame impingement on thermopile. If low, see “Pilot will not
remain lit”.
• Check thermopile for minimum of 300 mV when burner is switched
on.
• Check wiring to thermostat for breaks.
BV ONLY: Check for spillage at draft hood that may trip spill switch.
Flame lifting.
Leak in vent pipe.
• Check for leaks in vent connections.
Improper vent configuration.
• Check vent configuration with manual.
Terminal may be recirculating
flue gases.
• Check to see if terminal is on correctly.
• May need to install high wind termination cap.
• Contact dealer.
Glass fogs up.
Normal Condition: after the appliance warms up the glass will clear.
**Due to additives in gas, glass may get hazy during operation.** Clean as needed.
Blue Flames.
Normal during start up: flames will yellow as the fireplace heats up.
Flames are
burning “dirty” or
sooting.
Flame impingement.
• Check log positioning.
• Increase primary air by opening the venturi shutter and/or by
opening the vent restrictor.
See also “Burners will not remain lit.”
Remote control
doesn’t work.
Problem with the remote.
• One or more of the batteries are dead. See remote control
instructions.
Problem with fireplace.
• The on/off switch is turned to OFF.
• The gas control valve is turned to PILOT or OFF.
• The pilot has gone out.
BV ONLY:
Insufficient air
for combustion.
• Air tight house.
• A vacuum in room due to
another air-moving device.
• Supply make up air to the unit.