beautypg.com

Frame data – ProSoft Technology AN-X-PB User Manual

Page 28

background image

Page

24

AN-X-PBCAPT

November 2011

6: a11.000,621 d 0.000,029 d* * 56<0 SRDH

Frame Data

Delimiters

To suppress the inclusion of the start and end delimiters, include the
NoDelim option line.

Possible start delimiters are:

Start delimiter

Value

Description

SD1

0x10

Fixed Length, No Data

SD2

0x68

Variable Length, With Data

SD3

0xa2

Fixed Length, With Data

SD4

0xdc

Token Pass

SC

0xe5

Single Character, Short Ack

The end delimiter is shown as ED.

Example: Frames with delimiters:

144: a11.003,225,638 SD2 125<0 SRDH 00 ED

145: a11.003,248,060 SD2 0<125 DL 00 ED

146: a11.003,277,602 SD1 107<0 RFDL ED

147: a11.003,291,394 SD1 0<107 OK ED

148: a11.003,313,066 SD4 0<0

149: a11.003,328,733 SD1 108<0 RFDL ED

150: a11.003,343,524 SD1 0<108 OK ED

151: a11.003,364,566 SD4 0<0

152: a11.003,381,530 SD2 1<0 SRDH 00 ED

153: a11.003,404,488 SD2 0<1 DL 00 ED

The same frames, with no delimiters:

144: a11.003,225,638 125<0 SRDH 00

145: a11.003,248,060 0<125 DL 00

146: a11.003,277,602 107<0 RFDL

147: a11.003,291,394 0<107 OK

148: a11.003,313,066 0<0