beautypg.com

Liebert mcr – Emerson Liebert Power Solutions User Manual

Page 12

background image

4

12

Liebert GXT2

on-line UPS

ECM

(Environmental

Control Module)

BCM

(Back-up Cooling

Module)

Secure Door

lockable door

provides an extra

measure of

security by limiting

access to critical

equipment.

Sealed Door

specially designed

rubber gasket

provides NEMA12

sealing protection.

Where a minimal

amount of equipment

is needed, the

Foundation 44” tall

enclosure provides

compact protection.

Dual-Split Rear

Door available

Bundled UPS

systems available

Wall Mount Systems

12 U Hinge Body

“swing out” and 12”

depth Low Profile

available.

Internal Power

Distribution

A wide range of

installed power strips

is available to better

accommodate power

distribution needs

within the enclosure.

EX Cable

Management

Channel

This versatile option

helps to enhance

cabling organization

and internal airflow.

True On-Line Power Protection

Protecting The Edge

Of The Network

Liebert has brought together several of our

product solutions to create the IP Telephony

Availability System. Especially designed to

protect switches, routers and other critical

components, this solution is ideal for use in

remote locations such as branch offices,

retail stores and other edge of the network

applications. Housed in a Liebert

Foundation

wall mount enclosure or

freestanding enclosure.

The Liebert UpStation

®

GXT 2U, a true

double conversion UPS, delivers the high

level power quality required to fully protect

critical network switching components from

all power problems. Available in sizes from

700 up to 3000 VA.

Continuous Power Availability

In most cases, your critical routers and other

network components cannot be without

power even for scheduled UPS maintenance.

To meet this need, the Liebert 2U Power

Output Distribution (POD) system ensures

continuous uptime by providing

maintenance bypass capability as well as

power output distribution.

Power System Monitoring,

Communications &

Remote Control

The Liebert Webcard,

housed within the UPS,

will deliver SNMP and

web-management communications

capabilities to your power system, including

the ability to remotely reboot the switch by

cycling the UPS power off and on.

The Liebert IP Telephony Availability System, version 1.0, has

met the Cisco Technology Developer Partner Program test

criteria for interoperability with Cisco CallManager Express 3.1,

Cisco Unity Express, release 1.1.2, Cisco Unity 4.0 (3), and Unity

Bridge 3.0 (2).

Liebert MCR

Mini Computer
Room Enclosure

Liebert IP Telephony
Availability System