beautypg.com

Wiring dc power inputs – PLANET MGSW-28240F User Manual

Page 5

background image

5

3. Wiring DC Power Inputs

The 6-contact terminal block connector on the rear panel of the MGSW-28240F is
used for two DC redundant power inputs. Please follow the steps below to insert
the power wire.

100~240V AC

50/60 Hz

ON

AC POWER

OFF

DC POWER

ON

OFF

Ring R.O.

Fault

FAN2

FAN1

PWR

DC 2

DC 1

DC Input Range:

36V~60V

Fault

GND

GND

DO 1

DO 0

DI 1

DI 0

DC 2

DC 1

1

Insert positive / negative DC power wires into contacts 1 and 2 for DC POWER 1,
or 5 and 6 for DC POWER 2.

1. Tighten the wire-clamp screws for preventing the wires from loosening.

1

2

3

4

5

6

DC 1

Fault Alarm

DC 2

+

-

+

-

Note

The wire gauge for the terminal block should be in the range of 12
~ 24 AWG.
The DC Input range is from 36V to 60V DC.