LSI20101/LSI20102 SCSI Bus Boards

17

Connecting the Disable SE-A TERM or Disable SE-B TERM pins on J5
to ground turns off the onboard termination for the indicated physical bus.
See

Table 10

.

4.4.4 LEDs and Connector J4

The LSI20102 board contains three LEDs: one bus activity LED and two
SCSI TERMPWR status LEDs.

One green LED reflects the status of the SCSI bus busy signal.

Two yellow LEDs, one for each bus, indicate when TERMPWR is shorted
to ground. For instance, if TERMPWR is grounded somewhere in the
subsystem while TERMPWR is supplied by the board (when U8 switches
SW1 and/or SW2 are ON), the LED will light. See

Table 11

.

Table 10

Termination Control Connector J4

J4-Pin Number

Signal Name

1

Disable SE-A TERM

2

GND

3

Disable SE-B TERM

4

GND

Table 11

LED Description

LED

Color/Condition

Description

CR1

Yellow/ON

DIFF, TERMPWR shorted to ground

CR7

Green/ON

A-Side, BUSY (SCSI active on Side-A)

1

1. If the SCSI busy signal is active on A-side, it is also active on B-side and vice

versa.

CR10

Yellow/ON

SE, TERMPWR shorted to ground