Other Product Features Of The Liebert GXT2 10 kVA Include:
Low Total Cost Of Ownership
■
Standard two-year warranty
■
Uses less rack space leaving more
room for network equipment.
■
Batteries are shielded from
heat generating electronic
components, enhancing battery life.
■
Battery cutoff voltage
automatically adjusts based
on load, extending battery life
by preventing over-discharge
of batteries.
Reliability
:
■
Wider Input Voltage Window
Minimizes Battery Use — The Liebert
GXT2 10 kVA features a wide input
voltage window that allows the UPS to
support the critical load without having
to transfer to battery, extending system
availability for when battery back-up is
truly needed.
■
Internal automatic and manual bypass
— Assures continuity of power to critical
loads during system maintenance or in
case of internal fault.
■
Self-diagnostics — Automatically tests unit
electronics and batteries. Designed to
simplify maintenance and troubleshooting.
■
User-replaceable internal batteries —
Provide five minutes of runtime at
full load.
■
Hot-swappable operation — Unit features
three bays for one power module and two
battery modules. The chassis contains a
bypass switch that allows all modules to be
removed without powering down the
connected load.
Flexibility
■
Rack/tower configuration —
A single part number installs in either
configuration.
■
Automatic frequency detection —
The Liebert GXT2 10 kVA detects and
matches line input frequencies of either
60 or 50 Hz.
■
Additional runtime with 4U
battery cabinets — UPS cabinet includes
rear panel plug-n-play connections for
optional additional battery cabinets.
Use up to three cabinets for extended
battery runtime applications. Contact
Liebert Technical Support for longer
backup time solutions.
■
IntelliSlot
™
communications port —
Utilizes Liebert IntelliSlot Web Card to
provide SNMP and web-based monitoring
and control your UPS.
■
Includes Windows-based configuration
program — Allows various operating
parameters to be adjusted and tests to be
scheduled. This capability enables you to
customize the UPS performance to your
specific requirements.
■
Built-in serial communications for use
with Liebert MultiLink
™
Automated
Shutdown Software — Allows you to
monitor communication between the
UPS and a server, and ensures a graceful
unattended shutdown.
■
Built-in closure signals — Provides
notification to monitoring systems of
operating conditions including: on
battery, low battery, battery mode
shutdown and any mode shutdown.
■
Emergency Power Off (EPO) —
Terminal connections for a normally
open or normally closed emergency
power off switch.
Liebert GXT2 10 kVA 208V
Rear view, external
battery cabinet
External battery
Power
module
Liebert GXT2 10 kVA 208V
with external battery