Figure 4-3 cip tray with microphone, Table 4-5 cip tray cable connections – EFJohnson VR-CM50 User Manual

Page 39

background image

CRT-BASED ELECTRONICS ASSEMBLY PART I

4-3

February 1996

Part No. 004-3039-274

Figure 4-3 CIP TRAY WITH MICROPHONE

3. After the CIP tray is mounted, connect the follow-

ing cables using Table 4-5.

4. Mount the panel microphone (TDV-OP402/HR) to

the CIP:

All other microphone options, i.e., Dual Arm

Boom Microphone (TDV-OP403), Desk-Top Micro-
phone (TDV- OP404), and Auxiliary Microphone
Location (TDV-OP405), have customer specific
installation requirements and will not be included in
this Installation Guide.

Table 4-5 CIP TRAY CABLE CONNECTIONS

CIP Tray Board Connections (A1709228)

CIP PS Line Term Board Conn

ections

(A1709230)

1st Line Term Cable - P9 (I/O 1)

Connect to

P1 (I/O 1)

2nd Line Term Cable - P6 (I/O 2)

Connect to

P1 (I/O 2)

Red/Black CIP Power Cable

Connect to

P2 (13.7V DC) on CIP Tray

Ground Cable (A600966.18)

Connect to

CIP Power Supply

The ground cable is attached to the center
Pem nut on the rear of the CIP tray.

Remove the 5-32x1/2 Philips head screw at location marked
with a ground symbol on the rear of the power supply and
attach the ground cable.