Wiring diagram, Wiring and operation, Vbat – Whelen ID37UFX User Manual
Page 3
Page 3
WHT/GRN
BROWN
WHT/BLK
BLUE
ORANGE
WHT/ORG
BLK
RED
Scan-Lock
Flashing Takedown
Warning
Ground (-)
Low Power
Takedown
Warning
Override
Momentary Switch
SPST Switches
+VBAT
Wiring Diagram
All Fuses & Switches
Customer Supplied
Fuse @ 15 AMPS
Wire Color
Function
1 AMP Fuse
BATTERY
W
arning
W
arning
1 - 42
1 - 40
1 - 40
1 - 40
1 - 40
1 - 42
1 - 33
1-33
1 - 33
1 - 33
1 - 33
1 - 33
OFF
WARNING
FLASHING TAKEDOWN
FLASHING TAKEDOWN & WARNING alternate
TAKEDOWN
TAKEDOWN
TAKEDOWN
TAKEDOWN
WARNING OVERRIDE
(#12 is the Default Pattern)
WARNING OVERRIDE
(#12 is the Default Pattern)
FLASHING TD & WARNING OVERRIDE alternate
FLASHING TD & WARNING OVERRIDE alternate
TAKEDOWN & WARNING OVERRIDE alternate
TAKEDOWN
TAKEDOWN
TAKEDOWN
Flashing
TakeDown
Flashing
Takedown
W
arning &
Flashing TD
Takedown
W
arning
Override
Takedown
W
arning
Override
FUNCTION
AVAILABLE PATTERNS
SWITCH POSITIONS
off
ON
ON
ON
ON
ON
ON
ON
ON
off
ON
ON
ON
ON
ON
ON
ON
ON
off
ON
ON
ON
ON
ON
ON
ON
ON
off
ON
ON
ON
ON
ON
ON
ON
ON
Wiring and Operation:
WARNING! All customer supplied wires that connect to the positive terminal of
the battery must be sized to supply at least 125% of the maximum operating
current and FUSED at the battery to carry that load. DO NOT USE CIRCUIT
BREAKERS WITH THIS PRODUCT!
This lightbar is powered and controlled by an 8-conductor cable. The lightbar
operates in 4 basic modes. Take-down, Flashing Take-down, Warning Override
and Warning. You can operate in any one of these modes or combine them.
When you switch on more than one mode they will operate as follows:
• Take-down will override any other mode.
• Flashing Take-down will flash alternately with either Warning Override or
Warning if either is activated when Flashing Take-Down is activated.
• Warning Override will override Warning.
Example: If you switched on all four modes at once, Take-down would run. If you
turn Take-down off, (Leaving Flashing Take-down, Warning Override and Warning)
Flashing Take-down would alternate with Warning Override.
This allows you to run in one mode and then switch to another by only turning off one
switch instead of turning one off and another on. Example: If you activate Take-down
and Warning, you will run in Take-down mode. By switching off Take-down you will
immediately go to Warning (see chart below for other options).
White/Green - Scan-Lock™
The WHITE/GREEN wire allows you to choose from available flash patterns.
You must activate the lighthead to select a pattern:
TO CYCLE THROUGH ALL PATTERNS: To cycle forward, apply +12 VDC to the
WHITE/GREEN wire for less than 1 second and release. To cycle backward, apply
+12 VDC to the WHITE/GREEN wire for more than 1 second and release.
TO SET A PATTERN AS DEFAULT: When the pattern is displayed, allow it to run for
more than 5 seconds. The lighthead will now display this pattern when activated.
TO RESET TO THE FACTORY DEFAULT PATTERN: Turn off power and apply +12
VDC to the WHITE/GREEN wire while turning power on.
A normally open momentary switch is best suited for Scan-Lock operation.
Brown: Hi/Low Power
This feature works for Warning or Warning Override. With low power activated,
you may choose from four light intensities using Scanlock. The type of switch
depends on how you wish Hi/Low to function:
Latching Mode: (momentary switch) Apply positive voltage to the BROWN wire for
less than 1 second and the lightbar is “latched” into low power. Apply positive voltage
for several seconds and release to restore normal operation.
Level Mode: (toggle switch) Applying positive voltage to the wire for more than 1
second holds the lightbar in low power mode until voltage is removed.
Warning Patterns:
1.ActionScan™
2.SignalAlert™ 75 ALT
3.SignalAlert™ 75 ALT/IO/CH
4.CometFlash® 75 ALT
5.CometFlash® 75 ALT/IO/CH
6.DoubleFlash 75 ALT
7.DoubleFlash 75 ALT/IO/CH
8.SingleFlash 75 ALT
9.SingleFlash 75 ALT/IO/CH
10.LongBurst™ 75 ALT
11.LongBurst™ 75 ALT/IO/CH
12.SingleFlash 60 ALT
13.SingleFlash 60 ALT/IO/CH
14.SingleFlash 90 ALT
15.SingleFlash 90 ALT/IO/CH
16.SingleFlash 120 ALT
17.SingleFlash 120 ALT/IO/CH
18.SingleFlash 240 ALT
19.SingleFlash 240 ALT/IO/CH
20.DoubleFlash 120 ALT
21.DoubleFlash 120 ALT/IO/CH
22.ActionFlash™ 75 ALT
23.ActionFlash™ 75 ALT/IO/CH
24.ActionFlash™ 150 ALT
25.ActionFlash™ 150 ALT/IO/CH
26.MicroBurst™ ALT
27.MicroBurst™ ALT/IO/CH
28.PingPong™ 75 ALT
29.PingPong™ 75 ALT/IO/CH
30.FlimFlam ALT
31.FlimFlam ALT/IO/CH
32.Moduflash™ ALT
33.Moduflash™ ALT/IO/CH
34.Cylon 1 Lamp
35.Cylon 2 Lamp
36.Cylon Chaser
37.Eyeballs SYNC
38.Eyeballs IN/OUT
39.2 Eyeballs IN/OUT
40.Eyeballs CRAZY
41.CRUISE - LOW
42.CRUISE - HIGH
ALT = Alternating
ALT/IO/CH = Pattern cycles from
Alternating to IN/OUT to
Checkerboard
Flashing Take-Down
Patterns:
43. SingleFlash 240
44. DoubleFlash 120
45. ActionFlash™ 75
46. ActionFlash™ 150
47. MicroBurst™
48. PingPong™ 75
49. FlimFlam
50. Moduflash™
51. SignalAlert™ 75
52.CometFlash® 75
53. DoubleFlash 75
54. SingleFlash 75
55. LongBurst™ 75
56. SingleFlash 60
57. SingleFlash 90
58. SingleFlash 120
Take-Down
Configurations:
59. ALL
60. INNER
61. OUTER