beautypg.com

Top view, Front view, Input expansion table pa volume adjustment – Whelen CCSRN3 User Manual

Page 9: Radio repeat volume adjustment, Cencom module fuses, Input expansion module (optional), Control heads, Page 9, Isolated relay (outlet 8)

background image

Page 9

Input Expansion Table

PA Volume Adjustment

Locate the PA adjustment potentiometer on the right side of the
CenCom module. Using a small, flat-blade screwdriver, set the
potentiometer to its middle position. With the CenCom™ system on,
activate the PTT (Push To Talk) feature on the optional microphone.
Adjust the potentiometer until a satisfactory PA volume level is achieved
using a normal speaking voice.

Radio Repeat Volume Adjustment

To Adjust the Radio Repeat Levels: Before placing this unit into service,
the Radio Repeat output volume must be adjusted to satisfactory
operating levels. To adjust this level, a small, flat-blade screwdriver is
needed. Locate the Radio Repeat adjustment potentiometer on the
right side of the CenCom module. Set the volume of the vehicle’s two-
way radio to its normal operating level. Press the RAD button on the
control head to activate Radio Repeat. As incoming transmissions are
received, adjust the Radio Repeat potentiometer to set the desired
level. Turn the potentiometer clockwise to increase the level and
counter-clockwise to decrease the level.

CenCom Module Fuses

For ease of access, all of the amp/relay module fuses are accessible from
outside the case.

Isolated Relay (Outlet 8)

The position of the Output 8 fuse determines the function of the Brown,
Red and Orange wires. When the fuse is in Position 1, these wires act as
a Isolated 10 Amp Relay. When the fuse is in Position 2, the Brown and
Red wires act as Outlet #8. Refer to the schematic shown for the
electronic properties of this circuit.

Amp/relay Module
Fusing Information

Isolated Relay (Outlet
8)

F1

(POS.1)

Common (Orange/21)

Normally

Closed (Red/22)

Normally

Open (Brown/23)

Fuse in

Dry-Contact

Position

Fuse in

10 Amp Outlet

Position

F1

(POS.2)

+12VDC

LIGHTBAR

CTRL

HEAD

OUTPUT

2

20A

20A

MAIN

P

20A

OUTPUT

3

20A

OUTPUT

4

10A

OUTPUT

5

10A

OUTPUT

6

10A

OUTPUT

7

10A

T/A

FUSE

20A

OUTPUT

7

10A

OUTPUT

10A

POSITION

DRY

CONTACT

POSITION

OUTPUT 1

40A

ERR

H S

USB

L

WC POW

PA

SYSTEM

I/O

- 20 -

- 20 -

- 20 -

- 20 -

- 20 -

- 10 -

- 10 -

- 10 -

- 10 -

- 10 -

Top
View

SIREN FUSE

20A

- 20 -

Front
View

Positive Input 2

Positive Input 8

RED

GREY

2

8

3

9

13

5

11

15

4

10

14

6

12

16

Positive Input 6

Negative Input 4

Negative Input 8

BLUE

WHT/YEL

WHT/GRY

GREEN

WHT/ORG

WHT/VIO

ORANGE

WHT/BRN

WHT/GRN

YELLOW

WHT/RED

WHT/BLU

Positive Input 4

Negative Input 2

Negative Input 6

Positive Input 5

Negative Input 3

Negative Input 7

Positive Input 3

Negative Input 1

Negative Input 5

1

7

BROWN

VIOLET

COLOR

FUNCTION

Positive Input 1

Positive Input 7

WIRE CHART

WIRE SIDE VIEW

POS

1

9

2

3

4

5

6

7

8

10

11

12

13

14

15

16

Input Expansion Module (optional)

The optional input expansion module enables up to eight (8) non-CenCom
vehicle components and/or equipment to be integrated into the CemCom/
Cantrol network.

As shown in the tables below, connect the input wire of the desired device
to the appropriate wire. For example, if the device in question requires a
Positive input signal, that input wire would be connected to the BROWN
expansion module pigtail wire. In this example, that device would be
recognized as “INPUT 1” by the Cantrol system. However, if that device
requires a Negative input signal, that input wire would be connected to the
WHT/BRN expansion module pigtail wire. Note that this device would be
recognized as “INPUT 1” by the Cantrol system.

Control Heads....

A wide variety of control heads are available for use with this system.
The specific function of any button, slide switch or rotary knob can be
customized via the CenCom configuration software program. The
following pages will present all of the available control heads and their
default operating configuration.

This manual is related to the following products: