beautypg.com

Installation, Wiring, Page 2 – Whelen 70A02SAR User Manual

Page 2

background image

Page 2

3.281"

2.375"

1.187"

6.562"

1" diameter hole

1/4" mounting hole

(4 places)

Installation:

IMPORTANT! It is the responsibility of the installation technician to make sure
that the installation and operation of this product will not interfere with or
compromise the operation or efficiency of any vehicle equipment!

4.

Position the lighthead onto the mounting surface and secure to the vehicle

using the four supplied #6 x 1-1/2” sheet metal screws.

Wiring:

WARNING!

All customer supplied wires that connect to the positive terminal

of the battery must be sized to supply at least 125% of the maximum operating
current and FUSED at the battery to carry that load. DO NOT USE CIRCUIT
BREAKERS WITH THIS PRODUCT!

The 700 Series lighthead offers the user various features depending on the model.
Refer to the next page for wire designations and replacement parts.

Scan-Lock™ (White/Violet):
Note that the lighthead must be on to use the Scan-Lock™ feature except
where noted.

To advance to the next flash pattern - Apply +12VDC to the WHT/VIO wire for less
than 1 second and release.

To cycle backwards through the flash patterns - Apply +12VDC to the WHT/VIO
wire for more than 1 second and release.

To reset to the factory default flash pattern - Turn off power to the lighthead. While
applying +12VDC to the WHT/VIO wire, turn power to the lighthead on. Continue to
apply voltage to the WHT/VIO wire for 5 seconds. The default pattern will now be
active.

NOTE: A Normally Open momentary switch is suggested to activate the Scan-
Lock™ wire.

SYNC (Grey) - To SYNC two lightheads, configure both lightheads to display the
same Phase 1 pattern. With the power off, connect the Grey wires from each
lighthead. When the lightheads are activated, their patterns will be synchronized. To
configure the two lightheads to alternate their patterns, advance the pattern of either
lighthead to the Phase 2 mode of the current pattern. Remember, Phase 1 patterns
ALWAYS alternate with Phase 2 patterns!

Hi/Low Intensity (Violet) - This feature allows the user to step the unit down to low
power operation for nighttime use. Apply positive voltage to the VIOLET wire to put
the lighthead into low power. Remove the voltage from the VIOLET wire to restore
normal high power operation.

The table below provides wiring information for the 700 Series lighthead. Refer to the
appropriate flash pattern list as determined by the lighthead style:

WARNING! The LED models designated “Steady” must be connected to an
electronic flasher. Allowing the LED to steady burn will damage the lighthead
and void the warranty.

This product draws significantly less current than a

standard incandescent automotive bulb. If your flasher does not operate
properly, it may be necessary to replace your existing flasher module with a
Whelen 3TERM flasher module. Contact your sales representative for specific
vehicle application.

Caution: Permanent mounting of this product will require drilling. It is
absolutely necessary to make sure that no other vehicle components could be
damaged by this process. Check both sides of the mounting surface before
starting. If damage is likely, select a different mounting location.

1.

Using the dimensions shown, mark off and drill the four 1/4” diameter mounting
holes and the 1” wire hole into the mounting surface. Check measurements
before drilling.

2.

Install the flange grommet into the mounting holes then install a rubber
grommet (customer supplied) into the wire hole.

3.

Using appropriately sized wires (minimum 18 AWG wire), extend the lighthead
wires to their appropriate connections. Fuse the positive connections at 3
Amps and test operation of lighthead before securing it to vehicle.

1. SignalAlert™ 75 - ALT
2. SignalAlert 75 - SIM
3. CometFlash 75 - ALT
4. CometFlash 75 - ALT
5. DoubleFlash 75 - ALT*
6. DoubleFlash 75 - SIM*
7. SingleFlash 75 - ALT*
8. SingleFlash 75 - ALT*
9. ComAlert™ 75 - ALT
10. ComAlert 75 - SIM
11. LongBurst™ 75 - ALT
12. LongBurst 75 - SIM
13. PingPong™ 75 - ALT*

14. PingPong 75 - SIM*
15. SSNF 75
16. SingleFlash 60 - ALT
17. SingleFlash 60 - SIM
18. SingleFlash 90 - ALT*
19. SingleFlash 90 - SIM*
20. SingleFlash 120 - ALT*
21. SingleFlash 120 - SIM*
22. SingleFlash 300 - ALT
23. SingleFlash 300 - SIM
24. DoubleFlash 150 - ALT
25. DoubleFlash 150 - SIM
26. ComAlert™ 150 - ALT

27. ComAlert 150 - SIM
28. ActionFlash™ - ALT 50
29. ActionFlash™ - SIM 50
30. ActionFlash™ - ALT 150
31. ActionFlash™ - SIM 150
32. ModuFlash™ - ALT
33. ModuFlash™ - SIM
34. DoubleFlash - ALT 120*
35. DoubleFlash - SIM 120*
36. PingPong™ - ALT 120*
37. PingPong™ - SIM 120*
38. TripleFlash™ - ALT 75*
39. TripleFlash™ - SIM 75*

40. TripleFlash™ 120 - ALT*
41. TripleFlash™ 120 - SIM*
42. SignalAlert CAL - ALT*
43. SignalAlert SIM - ALT*
44. ActionFlash™/SingleFlash

60/120 - ALT*

45. ActionFlash™/SingleFlash

60/120 - SIM*

46. ActionFlash™/SingleFlash

120/TF75 - ALT*

47. ActionFlash™/SingleFlash

120/TF75 - SIM*

48. CalScan™ - ALT + SIM*

49. ActionScan™ - ALT + SIM
50. SteadyFlash 60*
51. SteadyFlash 75*
52. SteadyFlash 90*
53. SteadyFlash 120*
54. Steady / Steady*

* = California Title XIII compliant

1. SignalAlert™75
2. SignalAlert150
3. SingleFlash 375

4. SingleFlash 150
5. SingleFlash 75*
6. DoubleFlash 150

7. DoubleFlash 75*
8. CometFlash®75
9. ActionFlash

10. ModuFlash
11. ComAlert
12. ActionScan

13. SignalAlert
14. Steady
* = California Title XIII compliant

Sync-Capable Flash Patterns:
1.

SignalAlert™ 75 - Phase 1

2.

SignalAlert 75 - Phase 2

3.

CometFlash® 75 - Phase 1

4.

CometFlash 75 - Phase 2

5.

DoubleFlash 75 - Phase 1

6.

DoubleFlash 75 - Phase 2

7.

SingleFlash 75 - Phase 1

8.

SingleFlash 75 - Phase 2

9.

ComAlert™ 75 - Phase 1

10. ComAlert 75 - Phase 2
11.

LongBurst™ 75 - Phase 1

12. LongBurst 75 - Phase 2
13. PingPong™ 75 - Phase 1
14. PingPong 75 - Phase 2

Non-Sync Flash Patterns:
15. SingleFlash 60*
16. SingleFlash 90*

17. SingleFlash 120*
18. SingleFlash 300
19. DoubleFlash 150
20. ComAlert 150
21. ActionFlash™ 50
22. ActionFlash 150

23. ModuFlash™
24. ActionScan™
25. Steady

* = California Title XIII compliant

Split Pattern Table:

Standard Pattern Table:

SYNC Pattern Table:

CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

I M P O R TA N T W A R N I N G !

IMPORTANT! Before returning the vehicle to active service, visually confirm the proper operation of this product, as well as all vehicle
components/equipment.

SCREW, 6 X 1-1/2" PPHSMS SS

GASKET

FLANGE GROMMET
700 SERIES

1/4" MOUNTING HOLE (4)

This manual is related to the following products: