beautypg.com

Mounting: 1 inch (npt) pipe mount, Permanent mount, Temporary mount – Whelen 2015LPA User Manual

Page 2: Mirror mount bracket

background image

Page 2

# 4

X

1 / 2 "

PHILLIPS PAN
H E A D S M S

P C B
ASS'Y

OPTIC
DOME

BASE

#10 X 5/8"
PPH SMS

F A S T E X
GROMMET

When inserting the flash
tube assembly into the
strobe

power

supply

assembly, align the 3
prongs on the flash tube
with the slots in the
power supply.

BASE
SEAL

#6 X 5/8" PAN HD.
THX HD. SCREW

#6 X 5/16" HEX WSHR
HD THD FORM. SCREW

FLASH
T U B E
ASS'Y

I M P O R TA N T:
Keep drain hole
in base facing
rear of vehicle.

H

If you wish

to control

Hi/Low Power

externally, cut the VIOLET wire off at this
point and exit with the BLACK and RED
wires. Ground this wire to go to high
power. You may install an SPST switch
(customer supplied).

F L A S H PAT T E R N S E L E C T I O N

To achieve any of the 4 flash patterns,
you must either cut-out or leave-in one,
two, both or neither of the two jumpers. If
you do not touch the jumpers the beacon
will default to QuintFlash™.

PCB ASSEMBLY (COMPONENT SIDE)

JU1

BLK

JU2

RED

JU

6

Q u i n t F l a s h

D o u b l e F l a s h

R a p i d R a n d o m

A c t i o n F l a s h ™

JU1

JU2

IN
IN

CUT
CUT

IN

CUT

IN

CUT

FLASH PATTERNS

FLASH PATTERN SELECTION

HI/LOW

POWER

CONTROL

O - R I N G
GASKET

Assembly and Operation:

Specifications for Model 2015:

Input Voltage .................................................................. 12.8 / (25.6) VDC
Input Current......................................................1.7 Amps & .085 average
Input Power............................................................................... 21.5 Watts
Flashrate: QuintFlash™.......................... 72 QuintFlashes (5) Per Minute

DoubleFlash .......................... 115 Double Flashes Per Minute
RapidRandom......................150-370-150 Flashes Per Minute
ActionFlash™.... 1 QuintFlash & 4 Single Flashes Per Minute

Energy ........................................................6.4 / 1.6 / 1.6 / 1.6 / 1.6 Joules
Output Power............................................................................... 15 Watts

WARNING!The strobe power supply is a high voltage device. Do not

remove flash tubes or dismantle the strobe light head
assembly while in operation. Wait 10 minutes after turning
power off before starting work or trouble shooting.

Mounting:

1 Inch (NPT) Pipe Mount:

1.

Threading for a 1 inch (NPT) pipe mounting is precast in the base.
Feed power cable through pipe and connect cable to beacon.

2.

Screw strobe beacon to threads on the pipe, taking precaution not to
damage the power wires. NOTE: Do not tighten base too hard
onto pipe so as not to damage the threads on the base.

Permanent Mount:

1.

Use the base as a template and mark the three mounting holes onto
the mounting surface. After removing the base, mark in the center
between the 3 mounting holes, the location of the wire access hole.

2.

Drill the mounting holes using a #16 drill bit. Drill a wire access hole
using a 3/8” drill bit. Remove the burrs from the wire access hole so
as not to damage the wires. It is recommended that you install a
rubber grommet to further protect the wires. A gasket will be used
between the beacon base and the mounting surface.

3.

After connecting the beacon to the power cable, feed the wires
through the cable access hole and place the base with the gasket on
the mounting surface, lining up the mounting holes in the base with
the mounting holes in the mounting surface. Secure beacon firmly to
the mounting surface with the #10 X 5/8 Sheet Metal Screws.

Temporary Mount:

Magnetic/suction: Thoroughly clean the proposed mounting surface prior
to mounting. For suction cup mounting, wipe the suction cup clean, place
the beacon onto its mounting surface and apply gentle pressure to ensure
a good seal. The Magnetic/Suction Cups mount the same way as
standard suction cups but are best suited to a flat, steel surface.
Magnetic: Place beacon onto mounting surface and plug into cigar lighter.

WARNING! Beacons equipped with cigar cords are intended for

shortduration, intermittent operation only! Prolonged
operation requires the beacon to be wired to the vehicle.

WARNING! The presence of any temporarily mounted warning light

on the outside of a vehicle in motion is not
recommended and is at the sole discretion and liability
of the user!

WARNING! All customer supplied wires that connect to the positive

terminal of the battery must be sized to supply at least
125% of the maximum operating current and FUSED at
the battery to carry the load. DO NOT USE CIRCUIT
BREAKERS WITH THIS PRODUCT!

DC voltage models are polarity sensitive. If the positive and negative wires
are reversed the unit will not function. The fuse is installed between the
power source and the beacon, in the positive (+) wire (RED) and must be
fused at the battery. A 5 AMP Fuse is Recommended for this unit.

1.

Connect the RED wire on the beacon to positive voltage (+). A
customer supplied single pole single throw (SPST) switch may be
used to control the ON/OFF function of the beacon.

2.

Connect the BLACK wire on the beacon to a negative (-) ground.

10-24

ELASTIC

STOP NUT

(QTY 4)

10-24 X 5/8
U-BOLT
(QTY 2)

1.

Secure the bracket to the mirror
2 supplied U-Bolts and elastic

1.

or other part of the vehicle using the

stop nuts.

Mirror Mount Bracket

10-24 X 7/8
PPHMS
(QTY 3)

10-24

ELASTIC

STOP NUT

(QTY 3)

2.

using the supplied sheet metal

screws

Secure the Beacon to the bracket

and elastic stop nuts.

2.