1.0 INTRODUCTION
1.1 SCOPE OF MANUAL
This Operator's Manual covers the installation and operation of the Kepco RCW 1500W Series of
Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford
Avenue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of
your RCW Power Supply. This information can be found on the nameplate of the unit.
1.2 DESCRIPTION
The Kepco RCW 1500W Series consists of seven models of Switching Power Supplies, with a sin-
gle output as shown in Table 1. RCW power supplies are compliant with the Low Voltage Directive
(LVD) and carry the CE Mark. Units are designed to operate with a universal input voltage within the
range of 85 to 264V AC and may be operated with either 100-120V AC, or 200-240V AC, 50-60 Hz
(47-66 Hz) input. They will also operate on 125V to 370V dc input. The RCW 1500W Series
employs a light weight ferrite core transformer with 150 KHz typical switching frequency. The
Power Factor Correction Circuit has a typical switching of 80 KHz. Regulation is provided by pulse
width modulation. A FET power stage, operating in the forward conversion mode provides a
smooth isolated dc output. A resistor and thyristor "soft-start" circuit prevents excessive turn-on
current surge. Overvoltage protection and optically isolated remote TTL ON-OFF control are pro-
vided. Current limiting with automatic recovery from short circuit is featured. Units are enclosed in a
wrap-around aluminum case with a green LED "output present" light visible on the terminal side of
the case.
2.0 SPECIFICATIONS
Table 1 contains specifications and operating limits of individual RCW 1500W Series models. Table
2 contains specifications and operating limits common to all RCW 1500W Series Models. These
specifications are at nominal input voltages at 25°C unless otherwise specified.
TABLE 1. POWER SUPPLY RATINGS AND SPECIFICATIONS
MODEL RCW 1500W
3.3-300K
5-300K
12-125K
15-100K
24-65K
28-55K
48-32K
Output Volts d-c
(5)
3.3V
5V
12V
15V
24V
28V
48V
Adjustment Range
(7)
1.8-3.5
3.5~5.5
8.4~13.2
12.0~16.5
16.5~26.4
25.2~30.8
30.8~52.8
Maximum
Output
Ratings
(Amps/
Watts
50°C, amb A
300
300
125
100
65
55
32
50°C, amb W
1050
1500
1500
1500
1560
1540
1536
60°C, amb A
210
210
87.5
70A
45.5
38.5
22.4
60°C, amb W
735
1050
1050
1050
1092
1078
1075.2
70°C, amb A
120
120
50
40
26
22
12.8
70°C, amb W
420
600
600
600
624
616
614.4
Current Limit (Amps)
(1)
315-350
315-350
130-140
105-115
68-72
57.7-63.2
33.6-36.8
OVP Settings (Volts)
(2)
3.96-4.62
6.0-7.0
13.2-15.6
16.5-19.5
26.4-31.2
30.8-36.4
49.44-59.04
Efficiency %
typical
AC Input 120V
70
75
76
76
78
79
80
AC Input 240V
73
80
81
81
82
83
84
Ripple &
Noise
(3)
(mV, p-p)
output ripple (max)
100
100
100
100
100
100
100
spike noise (max)
(4)
200
200
200
200
200
200
300
Transient
Recovery
(6)
Recovery to
1%( 1 1 1 1 1 1 1 Excursion ±V max 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1) The Power Supply has a square type overcurrent characteristic, shutdown by undervoltage detection 2) The Power Supply has a shut-down type (by tracking) overvoltage characteristic. Recovery time to reset 40 seconds minimum 3) Source component 2x source frequency and switching component approximately 150 KHz, 10 to 100% load and ambient Ta = 25°C 4) Measure with a 50MHz bandwidth, 10 to 100% load and ambient Tc= 25°C 5) Output voltage setting = ±1% 6) A step load change from 50% to 100% of rated load current (with the following tr, tf load changes) produces no more than the output voltage excursions listed in the above table. The load change will be 5A/µs for Io>20A and 1A/µs for I<20A tr, tf of load change : 3.3v and 5v>30µs, 12v>12.5µs, 15v>10µs, 24v>6.5µs, 28v>5.5µs, 48v>3.2µs, 7) Recommended (using internal adjustment pot, par. 3.4). Using external pot (par.3.5) range = 10% to 110% of rated output voltage.