beautypg.com

5 linear accel/decel option, 1 potentiometers, Linear accel/decel option – SAF OPAL SS6 User Manual

Page 32: Potentiometers

background image

OPAL SS6 Reduced Voltage Starters

Page 25

5.5 LINEAR ACCEL/DECEL OPTION

CA385 - LINEAR ACCEL/DECEL CARD

This option card combined with a 60 tooth magnetic pulse pick-up or a tachometer provides
linear acceleration and deceleration independent of load. The ramp reference can be via
internal ramp generator or an auxiliary reference. A form C dry contact indicating when the
unit is running is available for external use and illuminated via LD1.

5.5.1 POTENTIOMETERS

POT

NAME

DESCRIPTION

RV1

STAB

Adjustment for stability of the ramping transition

RV2

TACH

SCALE

Sets up speed feedback for the regulator by adjusting voltage at TP1
(below JP2), CW decreases voltage at TP1
For internal ramp set TP1 for -9.2V or less at full speed
For aux ref set TP1 = maximum reference -0.667 or slightly less at
full speed

RV3

DECEL

Adjusts decel time of ramp, 5 - 50 seconds, CW increases time

RV4

ACCEL

Adjusts accel time of ramp, 5 - 50 seconds, CW increases time