OPAL SS6 Reduced Voltage Starters

Page 13

3.2 ANNUNCIATION

3.2.1 LED INDICATIONS

LED

NAME

COLOUR

DESCRIPTION

LD1

OVER
TEMP

RED

On when unit is faulted because of an open Over
Temperature switch at the OT terminal

LD2

READY

GREEN

This LED is illuminated when there are no faults

LD3

RUN

GREEN

Indication of run commanded to starter

LD4

MOTOR

OVRLD

RED

When lit an IOC (instantaneous over-current) or
an inverse time overload fault exists

LD5

+15V

GREEN

Illuminated when +15V power supply is okay

3.2.2 NEON INDICATIONS

NEON

NAME

DESCRIPTION

NE1

SCR 1,2

Should be lit during stop and extinguished when the motor is
up to speed. This represents the status of SCR 1 and 2

NE2

L1 ON

Indicates voltage is present on L1

NE3

SCR 3,4

Should be lit during stop and extinguished when the motor is
up to speed. This represents the status of SCR 3 and 4

NE4

L2 ON

Indicates voltage is present on L2

NE5

SCR 5,6

Should be lit during stop and extinguished when the motor is
up to speed. This represents the status of SCR 5 and 6

NE6

L3 ON

Indicates voltage is present on L3

3.3 ADJUSTMENTS

3.3.1 POTENTIOMETERS

POT

NAME

RANGE

DEFAULT

SETTING

DESCRIPTION

RV1

RATE

2-3 SEC

50%

Adjusts the time of the current ramping

CW rotation decreases the time

RV2

STEP

150-350%

50%

Adjusts the starting current or breakaway
torque
CW increases the torque (current)