RIGOL DG1000Z Series User Manual
Page 69
![background image](https://www.manualsdir.com/files/859124/content/doc069.png)
RIGOL
DG1000Z Quick Guide
25
disabled (if currently enabled).
Int and Burst will be displayed in the bottom of the screen.
4. To set the burst type and Cycles
Press Type to select NCycle. At this point, the Cycles in the screen is highlighted
and can be edited. Use the numeric keyboard to input 3 and press Sure.
5. To set burst period
Burst period is only available for N cycle burst in internal trigger and is defined
as the time from the start of a burst to the start of the next burst.
Press Burst Period to input 10 using the numeric keyboard and select msec
from the pop-up menu.
6. To select burst trigger source
Press Trigger Source to select Int trigger source.
7. To set the delay
Burst delay is only available for N cycle and infinite burst type. It is defined as
the time from when the generator receives the trigger signal to starts to output
the N Cycle (or Infinite) burst. Press Delay, and then use the numeric keyboard
to input 1. Then select msec from the pop-up menu.
8. To enable the output
Press Output1 to turn CH1 output on. At this point, the backlight goes on and
the [CH1] connector outputs the burst waveform based on the current settings.
9. To observe the output waveform
Connect the [CH1] connector to the oscilloscope using BNC cable. The
waveform is as shown in the figure below.
Figure 10 Burst