Retrotec Model QMG Specifications
Specifications
CFM
m
3
/s
m
3
/h
Maximum Flow (Free Air, 3 fans): 27,000
12.74
45,870
*Note: No power loss at 50Hz!
Maximum Flow (at 50Pa, 3 fans): 25,200
11.9
42,820
Minimum Flow (Range L1 at 10 Pa):
5
0.00236
8.5
Accuracy: Flow: ± 5%, ± 3% with Retrotec software and formal calibration
Pressure: ± 0.2 Pa or 1% whichever greater
Calibration Meets: Energy Standards: Canadian CGSB-149.1-2002 & SuperE, USA ASTM E 779 – 03,
European EN 13829 & CEN, UK TM-23 & ATTMA: TS-1
Dimensions
Weight
Fan: 26” x 25” x 9.5” (66 x 63.5 x 24.1 cm)
37 lb (16.8 kg)
Panels in Carry Case: 50” x 30.5” x 5” (127 x 77.5 x 12.5 cm)
26 lb (12 kg)
Fits Door Sizes: Width: 47” (120 cm)
Height: 81” (205 cm)
Fan Inlet Diameter 22” (56 cm)
Motor: 2 hp 3-phase, 2000W (100v to 260v, 50hz or 60hz, single phase power input)
Control: Using DM-2A (or optional Manual Speed Control)
QMG System Comes Complete With
Digital Gauge 1x 2-Channel DM-2A Digital Gauge with Automatic Control
1x 2-Channel DM-2 Digital Gauge without Control
1x DM-2A 3-Fan Splitter (controls 3 fans from one DM-2A)
Umbilicals, Cables, and tubing for Fan Control, Power, Room Pressure and
Flow Pressure for 3-fan Test
Fan 3 x 3300 High Power, Auto-switching, Fans with Automatic Control
1 set of Range Rings A, B, C8, C6, C4, C2, C1,L4, L2, L1 and Plug-set
Door 3-Fan Hard-Panel Door
Cordura Carry Case
See literature on gauges, fans, software, accessories and panels for additional information and options.
Options from Retrotec
Panel Cover – for
unused fan holes.
2 QMG with 6 fans in
one double door
Cloth Door for
1 fan
Modular Hard
Panel for 1 fan
Modular Hard
Panel for 2 fans
Now that is a tool bag
designed to handle
everything you could
possibly use while
testing. Laptop case
will fit as well.
Specifications subject to change without notice.