Digital gauge – Retrotec Spec-Blower Door 1000-SP110 User Manual
Page 2

CFM@50 calculation
eliminates the need
for an exact
test pressure.
ACH50 shown
directly on the
gauge.
*
Normalized flow,
CFM/sq ft required
in USA or
(cu m/h)/sq m
in Europe.*
EqLA at 50 Pa lets
you visualize the size
of the hole in ducts or
house.*
Digital Gauge
Umbilical helps
with tubing
organization.*
Frame Mount
easily velcro
gauge to frame.
* exclusive
Page 2 of 4
Page 3 of 4
The Retrotec DM32 displays every possible result and lets a user control fan speed via its touchscreen. Many features
are *exclusive to Retrotec.
“Set Speed”
and adjust with
intuitive up/down
arrow keys.*
Calculates Result
in any unit.
*
Results
at exactly the
pressure you
need.*
“Set Pressure”
control to any
pressure.
*
Settings
saved on
shutdown.
No need to
adjust every
time.
*
Dimensions
eliminate
calculations.
*
Baseline
automatically
subtracted.
Home
from any
screen
*
Result: Units Available: Example:
Pressure:
Pa, in WC, psf (lb/sq ft)
53.5 Pa
Flow:
CFM, L/s, cu m/s, cu m/h
253.5 CFM
Flow per area:
CFM/sq ft, CFM/100 sq ft, CFM/1000 sq ft,
(L/s)/sq m, (cu m/h)/sq m
0.25
Leakage Area:
EqLA, EqLA10 (Canadian), EfLA, EfLA4 (US): sq in,
sq ft, sq cm
12.8
Leakage Area per area: /100 sq ft, /sq m, /sq ft
1.15
Air changes per hour:
According to volume entered: /hr
2.7 ACH
EQLA10 sq in/sq ft
EQLA sq in @10.0Pa
CFM/100 sq [email protected]
DM32 Digital Gauge
Weight
12oz/340g
Size
5.70 x 3.73 x 1.4 in
14.5 Ч 9.5 Ч 3.5 cm
Power
USB to AC adaptor
4200 mAh internal
rechargeable battery
Rechargeable
internal batteries
save $200/year.*
Tapered connectors
best seal & easy disconnect.
Will not tear tubing.*
Network
control from a
computer.*