Basic programming guide – Remote Processing BASIC for the CX-10 Modbus User Manual
Page 26

BASIC PROGRAMMING GUIDE
2-17
END
Syntax:
END
Function:
Terminates program execution and returns to command mode.
Mode:
Run
Use:
65000 END
DESCRIPTION
The END instruction terminates Basic program execution. If no END instruction is used at the end of a
program, the last instruction automatically terminates the program. Use END after the body of your program
and prior to any subroutines.
Without an END after the main body of your Basic program and prior to any subroutine program lines,
BASIC-52 will attempt to execute any subroutines at the end of your program as if they were a continuation
of the main program. This will generate a C-STACK error whenever a RETURN is encountered.
RELATED
CONT, STOP, GOSUB, ON-GOSUB
ERROR
CAN'T CONTINUE The CONT instruction cannot follow an END instruction.
EXAMPLE
10
GOSUB 100
20
END
100
PRINT PI
110
RETURN
>run
3.1415926
If you remove line 20, a C-Stack error is returned.