The following table details the parameter configurations to meet Grade 3 requirements
in the UK:
Item
Grade 2
Grade
3
Explanation
USER CODES
4 digits
6 digits
NOTE: changing the number of code digits will require re-
defining all current user codes.
ANTI CODE
RESET
4 digits
6 digits
EVENT LOG
250
events
500
events
LightSYS2 always supports 512 events
ENGINEER
TAMPER
Not
required Required
For Grade-3, the system control bit “ENGR. TAMPER” shall
be defined as YES.
Menu = [Programming][System][Controls][Advanced]
YES: A Tamper event causes a Lockout condition which can
only be reset by the Engineer code or by Anti-Code.
NO: A Tamper event does not cause a Lockout condition
FAULT RESET
Not
required
Required
For Grade 3, the system control bit “Rest Fault” shall be
defined as YES.
Menu = [Programming][System][Controls][EN50131]
YES: A System Fault condition must be acknowledged by
the user
NO: A System Fault condition will reset automatically
when clear
DETECTOR
MASK AND
FAULT
Not
required
Required
For Grade 3, triple end-of-line termination is supported to
identify detector masking and fault. (fault for all Grades).
INHIBIT KEYPAD Not
required
Required
For Grade 3, 10 invalid code entry attempts will lock the
keypad for 90 seconds (relevant for all user codes and
operations – arming, disarming, etc.)
DUAL PATH
SETTING
PREVENTION
Required Required
If there is a communication fault with the ARC (by PSTN,
TCP/IP, GSM, or STU) the panel will not be ready to arm.