Summary of Version 3.0x Enhancements
This section describes the product enhancements available for LightSYS 2, firmware version
3.0 and above.
LightSYS 2 version changes were made in consideration of market requirements and
improvements to the product.
NOTE: The changes pertain only to expanded system capabilities, and do not entail changes
to the instructional procedures contained in the manuals
.
Table of Expanded System Capabilities
Capability
LightSYS 2
Firmware versions lower
than 3.0
LightSYS 2
Firmware versions 3.0
and above
Total Maximum Zones
Any combination of wired,
wireless or bus zones as
specified below:
32
50
Wired Zones
Up to 32
Up to 50
*
Wireless Zones
(1-way or 2-way)
Up to 32
Up to 50
Bus Zones
Up to 32
Up to 32
User codes & tags
Up to 16 user codes & tags
Up to 30 user codes & tags
Programmable outputs
Up to 14 outputs
Up to 32 outputs
Zone expander modules
Up to 3 modules
(8 zones each)
Up to 5 modules
(8 zones each)
Output expander modules
Up to 4 modules
(either 4 or 8 outputs each)
Up to 6 modules
(either 4 or 8 outputs each)
*
To connect 50 relay detectors, use single zone expanders (RP128EZ01) on zones 9 & 10,
and then add five 8 zone expanders (RP432EZ08) to reach 50 zones.
Grade 3 Features
By default, LightSYS 2 is configured to Grade 2. In order to meet Grade 3 requirements
(supported from LightSYS firmware version 2.65 and up), go to:
Engineer MenuProgramming1)System5)Settings4)Standard4)EN 50131 (G3)
NOTE: This will invoke a default of the system parameters.