beautypg.com

External reset connection, Figure 5. reset connections, 20 ma transmitter power supply – Precision Digital PD6820 User Manual

Page 15: Power supply slide switch to 9-36 vdc

background image

PD6820 Loop-Powered Process Meter Instruction Manual

15

4-20 mA

Transmitter

Power

Supply

SAFE-TOUCH

BUTTONS

BACKLIGHT

POWER

UNLOCK

LOCK

LOOP

9-36 VDC

+ - + -

SIGNAL

BACKLIGHT

Power

Supply

Slide Switch to

9-36 VDC

+ - + -

OUTPUT

RESET

Figure 4. Input Connections with Externally-Powered Backlight


It is possible to use the same transmitter (signal loop) power supply for the externally
powered backlight. The backlight circuit will draw 25 mA in addition to the loop circuit.

External Reset Connection

External reset connections are made to two terminals labeled RESET. Connect to a
contact closure source such as a relay or a pushbutton as shown in Figure 5.

SAFE-TOUCH

BUTTONS

BACKLIGHT

POWER

UNLOCK

LOCK

LOOP

9-36 VDC

+ - + -

SIGNAL

BACKLIGHT

+ - + -

OUTPUT

RESET

Figure 5. Reset Connections