18 - MAINTENANCE AND CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
In order to clean the exchanger and the pipe unit, while the stove is cold, proceed in the following manner:
• Remove the top “B”
• Remove front panel “A” (follow the instruction in the dedicated paragraph)
• Remove the four screws “C” and the two screws “D”
• Take out profile “E”
• Now remove the two screws “F”
• Lift cover “G” with turbulators “T” and put it somewhere safe to remove the ash.