Chapter 5

INSTALLATION AND USE MANUAL

page

15

Operation

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

3.3. AUTOMATIC MODE

Once ventilation is turned on in manual mode, by pressing the red

MAN/AUT of the radio remote control, the device goes to AUTOMATIC

mode. The mode can be recognized by the fact that all the sound

signals emitted by the control unit in this status are long

beeps.
The yellow + and - buttons are used to increase/decrease the speed of

the fan from 1

st

to 4

th

and vice versa. The control unit responds with a

number of short beeps that corresponds to the selected speed:

1

st

speed

= 1 long BEEP

2

nd

speed

= 2 long BEEPS

3

rd

speed

= 3 long BEEPS

4

th

speed

= 4 long BEEPS

Ventilation is turned on and off exclusively by the temperature of the

thermostatic probe.

AUTOMATIC START BY MEANS OF THE PROBE:
If the temperature detected by the probe is greater than 45°C, the fan

comes on at the set speed (1

st

speed) and an internal timer is activated

that performs a countdown starting from 40 minutes. This period of 40

minutes is called the “

warm-up phase".

After 40 minutes, if the temperature of the probe exceeds 65°C, it

means that the internal temperature is rising because the fireplace

stove is coming up to operating power, and therefore the fan must stay

on. After 40 minutes, if the probe does not reach 65°C, it means that

the power of the fire is low and the ventilation must be shut off.
If the user changes the speed while the system is between 45°C and

65°C, this is interpreted as a request for ventilation. The system goes

back to the

warm-up phase; the timer is reset to 40 minutes and the

countdown begins.

AUTOMATIC SHUTDOWN BY MEANS OF PROBE:
If the temperature probe drops below 65°C, ventilation is shut off.

3.4. OTHER FUNCTIONS OF THE CONTROL UNIT FC 715

STAND-BY: The fan is off because the blue ON/OFF button of the

radio remote control has been pressed. Shutdown is signalled by a long

beep.
SAFETY: In STAND-BY status, if the temperature exceeds 150°C, the

fan comes on at speed 1 and the system goes into AUTOMATIC mode.

Ventilation continues until the temperature drops below 65°C.
STATUS RECOVERY: the system automatically saves, in non-volatile

memory, the last power setting made by the user, allowing continuation

at the speed after a power outage.

3.4.1. Setting transmission code of the radio remote

control

The radio remote control and the control unit are set with a neutral

code that makes it possible to check operation of the ventilation kit

immediately, before the cladding is completely installed.