Installation and assembly

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

2.5.4. Ducts for kit VF 180 m

3

/h (Airsystem B70)

Differently from the kit VF 480-620 m

3

/h, the kit VF 180 m

3

/h does not

require ducts, since the lower power of the fans and their position

with respect to the fireplace stove allow proper operation of the system

provided a considerable quantity of air is provided under the unit.
Considering that this type of fireplace is normally set in an internal wall

of the home and it is almost never possible to provide ducts to the

outside of the home as with the previously described model, the

ventilation air must all be drawn from the room of installation, using the

air intakes on each side of the cladding
It is necessary to provide two air intakes with a net minimum section

of 150 cm

2

on both sides of the cladding that allow a continuous

exchange of oxygen under the fireplace stove

(figure 9).

If the air intakes are not sufficient, the fans will also

draw the air required for combustion, and this will

compromise proper operation of the product.

DIAGRAM OF AIR INTAKES ONLY FOR MODEL AIRSYSTEM B70

Fire bed

Fire bed

Ventilation

and combustion

air intake grille

Ventilation

and combustion

air intake grille


It is advisable to use two grilles of at least 20x10 cm

Remember that:

All of the air intakes must be equipped with shutters than can

be controlled from the outside and that are equipped with

insect protection.

The air intake section is considered net, therefore the area of

any obstructions must be considered (mesh, etc.)

The filters or meshes need to be cleaned periodically to ensure

air can pass through them.

Do not for any reason obstruct the air intakes if the

fireplace stove or ventilation kit is in operation

Figure 9 - Air intake grilles for ventilation and combustion air