MCZ FC700-715 - 180+180 m3/h User Manual
Page 11

Chapter 2
INSTALLATION AND USE MANUAL
page
11
Installation and assembly
Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
2.6. COMPONENTS OF KIT VF 480 m
3
/h WITH CONTROL UNIT FC715
Diagram 1 – Wiring Kit VF for Forma with control unit FC 715
FUSE
ACOUSTIC SIGNAL EMITTER
LINE SIGNAL
LED
1
2
3
4
5
6
Yellow-green
Brown
Blue
7. Radio remote control complete with internal battery
8. Fan cable with plug and terminals
9. Supply cable with plug and socket
10. Power supply device with built-in radio receiver
11. Fan of 480mc/h
12. Silicon probe cable with snap-in connection
complete with electronic probe
IMPORTANT!
PRIOR TO INSTALLATION, ENSURE THAT THE
KNOCKOUT PANELS LOCATED ON THE SIDE OF THE
FIREPLACE STOVE HAVE NOT BEEN REMOVED.
IF THE KNOCKOUT PANELS HAVE BEEN REMOVED (SEE
PAGE 19), YOU WILL NEED TO PUT THEM BACK OR
CLOSE OFF THE HOLES WITH STEEL PLATES.