Sp. 60, When the or indicators flash orange warning, When the or indicators are off normal – Epson EMP-TWD10 User Manual
Page 62

60
Lamp error/Lamp failure/Lamp cuts out/Lamp cover open
Wait for approximately 1 minute and 30 seconds, and check for a
blown lamp.
Clean the air filter and the air intake vent.
The lamp is not broken
Reinsert the lamp then turn on the main
power switch on the main unit and press
.
If the condition is not
fixed once the lamp is
re-inserted
The lamp is broken
Contact your dealer for further advice.
When using this unit at high altitudes, that is 1500 m or more above sea level, set “High Altitude Mode”
to “On”.
When the
or
indicators flash orange
Warning
: lit
: flashing
: off
High temperature
alarm
You can continue
projecting in this state.
Projection stops
automatically if
subsequent high
temperatures are
registered.
Check the 2 items listed.
• Move this unit away from
the wall at least 20 cm.
• Clean the air filter.
If there is no improvement when
you press
and switch the
power on, discontinue use and
disconnect the power cable from
the electrical outlet. Contact your
local dealer or the nearest address
provided in the Inquiries.
Lamp replacement notification
It is time to replace the lamp. Replace the lamp with a new one as soon as possible. Do not continue to
use the lamp in this state, otherwise it may explode.
When the
or
indicators are off
Normal
: lit
: flashing
: off
Standing-by
Shows that the unit is ready to be used.
During warming
up (Approx. 20
sec)
In warm-up mode, pressing
or
has no effect.
Do not unplug the power cable during warm-up. This may reduce the lifespan of the
lamp.
Projection in
Progress
Cooling down
(Approx. 5 sec)
The operation of all remote control and main unit buttons is suspended during cool-
down. Enters stand-by mode once cool-down has completed.
Do not unplug the power cable during cool-down. This may reduce the lifespan of
the lamp.
Break
Press
to return to normal playback.
Image being
turned Off
The Power switch is on but the projection lamp is off. Press
to turn the
projection lamp on.
Red
If the error continues
Orange
Green
Orange
Green
Orange
Orange
Green
Green
Green
Green
Green
Green
Green
Orange
Green
Green
Green
Green
Orange