Preliminar y, Installation, Mounting the switcher – Extron electronic MAV Plus User Manual
Page 20: Rear panel views

CrossPoint 450 Plus and MAV Plus Switchers • Installation
2-2
Installation
PRELIMINAR
Y
Mounting the Switcher
The matrix switcher BMEs are housed in rack-mountable, 6U (sync and video BMEs)
or 7U (audio BMEs) high metal enclosures with 19" rack ears. If desired, rack
mount the switcher BME as follows:
1.
Insert the switcher BME into the rack, aligning the holes in the mounting
bracket with those in the rack.
2.
Secure the switcher BME to the rack using the supplied bolts.
Rear Panel Views
All connectors for all switcher BMEs are on the rear panel. Figure 2-1 shows a
CrossPoint 450 Plus 6464 Sync BME, which has a feature set similar to all of the
features of all of the video and sync switcher BMEs with the following exceptions:
• The Sync Termination DIP switches (
c
) are found on the sync BME only.
• The External Sync BNC connection (
k
) is found on the MAV Plus and
CrossPoint 450 Plus video BMEs only.
Figure 2-2 shows a MAV Plus 6464 Stereo Audio BME
.
C
Use electrostatic discharge precautions (be electrically grounded)
when making connections. Electrostatic discharge (ESD) can damage
equipment, even if you cannot feel, see, or hear it.
C
Remove system power before making all connections.
N The 3248, 3264, 4832, 4848, 4864, 6432, 6448 matrix sizes are housed in the
same enclosure, but have fewer input and output connectors to accommodate
their smaller matrix sizes.
4
8
3
7
2
6
1
5
LAN
ACT LINK
RESET
REMOTE
Rx
Tx
2A MAX
LISTED
1T23
I.T.E.
C
U S
12
16
11
15
10
14
9
13
OUTPUTS 1 - 16
20
24
19
23
18
22
17
21
28
32
27
31
26
30
25
29
OUTPUTS 17 - 32
36
40
35
39
34
38
33
37
44
48
43
47
42
46
41
45
OUTPUTS 33 - 48
52
56
51
55
50
54
49
53
60
64
59
63
58
62
57
61
OUTPUTS 49 - 64
4
3
2
1
8
7
6
5
12
11
10
9
16
15
14
13
20
19
18
17
24
23
22
21
28
27
26
25
32
31
30
29
36
35
34
33
40
39
38
37
44
43
42
41
48
47
46
45
52
51
50
49
56
55
54
53
60
59
58
57
64
63
62
61
Rx
Tx
4
-
+
BME COMM
IN
OUT
BME
ADDRESS
EXT
SYNC
INPUTS
75
510
1 2 3 4 5 6 7 8
75
510
9 11 13 15
10 12 14 16
ANAHEIM, CA
12
8
9 10
6
11
2
2
1
3
7
Rx
Tx
Figure 2-1 — CrossPoint 450 Plus / MAV Plus 6464 sync or video matrix