Problem
Cause
Remedy
Will not run
switch is not “on”
switch “on”
unit is not plugged in
Insert plug
Fuse blown
replace fuse
Water tank full
empty water tank
Dehumidifier inefficient
Filter blocked
Clean filter
Inlet or outlet vents restricted
remove restriction
doors or windows open
close openings
refrigerant leak
contact sealey dealer
Water leaking from unit
Dehumidifier is not level
Adjust position of dehumidifier
Tank float not shutting down unit
contact sealey dealer
error codes
Problem
e1
Humidity sensor faulty
e2
refrigerant sensor faulty
6. TROUBLESHOOTING
5.1.
Cleaning Air Filter
the dehumidifying capacity is lowered when the air cleaning filter becomes clogged.
5.1.1. open the front door of the unit.
5.1.2. lift up the filter element from the bottom as shown in fig.3 and lift out of the holder.
5.1.3. to dislodge the dust from the filter, use a vacuum cleaner or tap it lightly.
5.1.4. If the filter is very dirty, wash it carefully in water with a neutral detergent, then rinse well with clean water and leave until dry.
5.1.5. to refit the air filter, locate the top of the element into the locating bracket at the top of the door and then locate the lower section into
the lower bracket.
5.1.6. close the door of the dehumidifier.
5.2. Storage
5.2.1. unplug the unit, bundle the power cord, and hang the bundled cord at the back of the unit.
5.2.2. remove the water collection tank and empty the water out of it. Wash the inside of the tank with clean water.
DO NOT remove the
float lever from the tank. Wipe off the water on the outside of the tank with a cloth. replace the tank in position.
5.2.3. clean the air filter (see 4.1).
5.2.4. When the unit is to be stored for a long time, wipe the dehumidifier over with a dry soft cloth. to remove dirt, wipe over with a very
slightly dampened cloth (never use a wet cloth for cleaning the controls). to avoid deformation or cracking, do not use benzine,
thinner or liquid cleaners.
5.2.5. When storing, place in a safe, dry, childproof location. stand the unit upright and avoid exposure to direct sunlight.
5. MAINTENANCE
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.