Fig.3 – Sealey SDH70 User Manual
Page 3

fig.3
drain plug and continuous draining hose connection.
4.2.
Defrosting Operation
the evaporator within the dehumidifier frosts during the dehumidifying operation at a room temperature of approximately 15°c or less.
the defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes.
the dehumidifying function will stop during the defrosting operation.
DO NOT disconnect the plug or turn off the unit during the defrosting
operation.
Note: this dehumidifier does not have a cooling function, it produces heat during operation and the room temperature will rise by 1°c to 4°c.
the temperature increases while it is operated in a closet, or similar. the temperature will rise because doors and windows are closed
and heat is produced from other appliances in the room and from sun radiation. Furthermore, a drier environment is less expensive to
heat.
4.3. Emptying the Water Collection Tank
during the dehumidifying operation, water is collected in the water collection tank. When the tank is full of water, the dehumidifier stops
operating automatically and the warning buzzer beeps twice. the unit will not restart until the water collection tank has been emptied.
4.3.1. open the dehumidifier door and remove the hose from the water collection tank. then remove the tank (fig.3).
4.3.2. Hold the tank by the handle and carry it carefully to an emptying point.
4.3.3. empty the water out of the tank.
4.3.4. replace the tank in the dehumidifier, making sure it is properly back in place; the unit will not restart if it is not fitted correctly.
4.3.5. Insert the drain hose into the tank.
4.4.
Continuous Draining
4.4.1. If there is a place suitable for draining, continuous draining can be carried out. the continuous operation enables the dehumidfying
operation to continue uninterrupted.
4.4.2. turn off the dehumidifier, disconnect the power plug and remove the water collection tank.
4.4.3.
Attach the short length of hose to the plastic bulkhead fitted to the casing, secure with a hose clip. see fig.3 bottom left.
4.4.4.
Attach a suitable length of hose; it should have an inner diameter of 16mm (5/8"), secure with a hose clip. see fig.3 bottom right.
4.4.5. replace the tank in the dehumidifier, making sure it is properly back in place; the unit will not restart if it is not fitted correctly.
4.4.6. continue to use the dehumidifier as normal.
Slide filter filter
vertically to remove
Ø17.2mm Hose connection
tank full sensor
drain to tank option
sdH70 Issue: 1 - 26/11/14
Original Language Version
© Jack sealey limited