Installation installing the tap, Flushing the tap, Operation bringing into use – Miomare Z31166D User Manual
Page 4: Setting the temperature limiter

4 GB
Keep all the safety advice and instructions in a
safe place for future reference!
Installation
Installing the tap
Turn off the main water supply to prevent serious
leakage of water. Allow any remaining water
in the pipework to drain.
Install the tap as shown in Figs. A and B.
CAUTION! Do not bend the hoses or place
them under tension. Otherwise material damage
could result.
Flushing the tap
The tap must be flushed through before first use
to remove any dirt. To do this, follow these steps
(see Fig. C):
Screw the mixer nozzle
7
off.
Open the main water supply and allow the
water to run for two minutes.
Then screw the mixer nozzle on again.
Operation
Bringing into use
Note: If the tap has not been used for a long period
flush the pipes through thoroughly in order to avoid
stagnation and build-up of residues in the drinking
water supply.
Open the main water supply.
Lift the control lever
8
and swivel it to the right
or left to regulate the strength or temperature
of the water flow.
Hot water:
Swivel the control lever to the left.
Cold water:
Swivel the control lever to the right.
Check that the mixer tap is working properly.
To do this, swivel the lever into all the possible
positions. Please check the connections regularly
for leaks.
Setting the temperature limiter
The cartridge
13
in this unit has a temperature limiter.
This function is not activated in the factory (neutral
setting).
CAUTION! Change the temperature limiter
setting only after the tap has been installed.
Turn off the main water supply.
Remove the red / blue hot / cold label
10
carefully by a small flat screwdriver (see Fig. D).
Release the lock screw
9
by turning it anti-
clockwise using a hexagon socket screw key.
CAUTION! Do not take the screw completely
out; just loosen it until the control lever can be
easily taken off.
Take off the control lever.
Loosen the cartridge end ring
11
by hand,
then screw off the cartridge locking ring
12
by using a pipe wrench.
Now pull the setting ring
15
upwards with the
help of a screwdriver.
Note: Do not remove the cartridge.
Place the setting ring in the desired position as
shown in Fig. E.
Tighten the cartridge locking ring
12
onto the
lever arm again by using a pipe wrench, then
tighten the cartridge end ring
11
by hand.
Place the control lever back on to the lever
arm and tighten the locking screw by turning it
clockwise using a hexagon socket screw key.
Press the red / blue hot / cold label
10
into the
opening.
Turn on the main water supply and check the
temperature limiter.
88891_mio_Spueltisch-Armatur D_Content_LB4.indd 4
18.02.13 12:36