Trouble shooting, Mt gb – Florabest FLV 1300 A1 User Manual
Page 54
54
MT
GB
Trouble shooting
Problem
Possible cause
Remedy
Abnormal noises,
clatter or
vibrations
Foreign body on cylinder
Remove foreign body
Damaged sprung tines or
cylinder knives
Exchange cylinder
Cylinder incorrectly
mounted
Install cylinder correctly (see
chapter on exchanging the cylinder)
Toothed-belt slip
Repair by After-Sales Service
Implement does
not start
No power
Check power socket, cable, line;
repair only by qualified electrician
ON / OFF switch defective
Repair by After-Sales Service
Carbon brushes worn out
Motor defective
Motor fails
Blocked by foreign body
Remove foreign body
Grass is too long
Mow beforehand; see chapter
“Operation”
Clogged discharge
Clean discharge
Overload protection tripped Allow implement to cool down for
about 1 minute
Work result not
satisfactory
Sprung tines of aerator
cylinder worn out
Exchange cylinder
Knives of verticutor cylinder
blunt or damaged
Exchange cylinder
Toothed belt defective
Repair by After-Sales Service
Transport Position or
incorrect Working Position
selected
Select Working Position 1 or
Readjust Position 2-4 (see chapter
“Setting the Working Positions)
Grass is too long
Mow beforehand; see chapter
“Operation”