3. Hang the cable strain relief

(19a) on the upper handle bar

(4).

Attach the clip ring to the ten-

sion adjuster bracket (19b) be-

neath the cable tension adjuster

(19a) on the upper handle (4).

4. Use the screws and wing nuts

(5b) to firmly secure the upper

handle bar (4) to the two centre

bars (15).

5. Fasten the electric cable (16)

to the bar with the two cable

clamps (14a+b).

Mounting and emptying the

collection bag

WARNING: Never operate the

implement without the impact

protector. Danger of Injury!

Assembling the collection bag:

The collection bag is delivered in a folded

state and must therefore be assembled

before it is mounted on the implement.

C

1. Assemble the collection bag

rods (22).

2. Slip the plastic straps (24) over

the collection bag rods.

Mounting the collection bag

on the implement:

3. Lift the impact protector (9).

4. Push the pins on the collection

bag rods (23) into the socket in

the implement case (10).

5. Release the impact protector so

that it holds the collection bag

(6) in its position.

Removing and emptying the

collection bag:

6. Lift the impact protector (9) and

take out the collection bag (6).

Operation

Please observe local regulations

concerning noise protection. It is

quite possible that local rules and

regulations may limit the time of

implement operation or even pro-

hibited its use on certain days (e.g.

Sundays and holidays), and dur-

ing certain times of the day (noon,

night hours) and in certain areas

(e.g. spars, clinics, etc.).

Setting the working positions

The implement has 5 principal position set-

tings:

Setting 0 :

Transport position

This position sets the maximum safety

spacing between the tool and the floor.

Setting 1 :

Working position

Set this position when working with a new

implement.

Settings 2 - 4 : Readjustment posi-

tions

The working position can be lowered with

increased knife and sprung tine wear.

Wear can be identified from an increas-

ingly poor result.

The readjusting depth amounts to approx.

3 mm per setting. Use the millimeter scale

readings for fine setting.

When the implement is delivered

it is in the Transport Position 0 set-

ting.

The implement must be switched off to

set the working position. Press the setting

button

(see

A

No. 13) down and turn it to the

required position until it locks in place (the

button immediately rises again).