beautypg.com

Finishing the installation – Kichler 300008 User Manual

Page 8

background image

7

Fig. 16

Fig. 17

Step 1. Tuck connections neatly into ceiling
outlet box.

Step 2. Slide the canopy up to ceiling and
over the two screws on hanger bracket. Rotate
canopy clockwise, next, while holding the
canopy with one hand, slide the canopy cover
over the screws and rotate clockwise until
tight. NOTE: adjust the canopy screws as
necessary until the canopy and canopy cover
are snug. (Fig.15)

Warning: Make sure the "Check Tab" at the
bottom of the hanger bracket is properly
seated in the "Registration Slot" on the side of
the hanger ball before attaching the canopy to
the bracket. Failure to properly seat the
"Check Tab" could damage the electrical wires
when to ceiling fan blade direction is changed
while the fan is running.

Step 3. (Fig. 16) Receiver to House Supply
Wires Electrical Connections: Connect the
black (hot) wire from the ceiling to the black
wire marked "AC in L" from the receiver.
Connect the white(neutral) wire from the
ceiling to the white wire marked "AC in N" from
the Receiver. Secure the wire connections
with the plastic wire nuts provided.

Step 4. (Fig. 16) If your outlet box has a
ground wire (green or bare copper) connect it
to the fan ground wires; otherwise connect the
hanging bracket ground wire to the mounting
bracket. Secure the wire connection with a
plastic nut provided. After connecting the
wires, spread them apart so that the green
and white wires are on one side of the outlet
box and black and blue wires are on the other
side. Carefully tuck the wire connections up
into the outlet box.

Note: Fan must be installed at a maximum
distance of 30 feet from the CoolTouch

TM

Remote Transmitter for optimal signal
transmission between the transmitter and the
fan's receiving unit

Outlet box

Hanger

bracket

Canopy

Canopy cover

Screws

8. FINISHING THE INSTALLATION

White (neutral)

Green or bare
copper (ground)

White ("AC IN N")

Outlet box

Black (hot)

Black ("AC IN L")

Receiver

White (neutral)

White ("to motor N")

Ground
(green)

(Connect to
ground wire on
hanger bracket
if no house
ground wire
exists.)

Black ("to motor L")

Blue (for bottom light)

Orange (for upper light)

Blue (for bottom light)

Black (motor)

Orange (for upper light)