Maintenance and service – Enviro Cara User Manual
Page 9
9
Maintenance And Service
R
outine
m
aintenance
:
At least once a year, run through the following procedures to ensure the system is clean and working
properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not
blocked by anything. The pilot flame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufficient to allow access for maintenance and service
Warning: Failure to position the parts in accordance with this manual, or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a
qualified agency.
c
Leaning
t
he
P
ainteD
s
uRfaces
:
Painted faces should be wiped with a damp cloth periodically.
c
heck
P
iLot
anD
b
uRneR
f
Lames
:
Figure 7: Door Removal / Installation.
IMPORTANT: If the door is not engaged
properly on the hooks, damage to the
fireplace and/or floor, personal injury, or
even death may occur.
1. Turn the unit off and wait until it has
cooled down.
2. Remove the cast iron louvers from above
the door by lifting the louvers up and
out.
3. Pull the two (2) door hooks, on top of the
door, forward and up (see Figure 7).
4. Lift the glass door assembly straight up
and out.
Ensure the door is properly fastened before
attempting to light the appliance. To re-
installing the glass door, slide the three (3)
door hook slots, on the bottom of the door,
over the three (3) door hooks on the unit.
Pull the two (2) door hooks, on top of the
door, forward and slide them into the two
(2) door hook slots.
Periodically do a visual check of the pilot flames. One flame
should encompass the ignitor and thermocouple and the
other should burn over the burner ports (see Figure 6). Also
check that the burner is operating correctly, refer to Figure
59 or the Front Cover.
g
Lass
D
ooR
R
emovaL
:
Figure 6: Pilot Flame.