Initial installation – Enviro Cara User Manual
Page 14
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING: Operation of this heater when not connected to a properly installed and maintained venting
system can result in carbon monoxide (CO) poisoning and possible death.
P
RePaRation
f
oR
i
nstaLLation
:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8
m) of the stove.
• The flow of combustion and ventilation air must not be obstructed.
c
LeaRances
to
c
ombustibLes
:
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
Figure 23: Clearance to Walls in an Open
Area, refer to Table 3.
Table 3: Clearance to Walls in an Open Area, refer to Figure 23.
Letter
Description
Clearance
A
Sidewall to unit
11 inches (279 mm)
B
Backwall to unit
2.5 inches (64 mm)
C
Corner to unit
2.5 inches (64 mm)
D
Ceiling to floor
90 inches (2286 mm)
E
Floor (on hardwood
and linoleum)
0 inches (0 mm)
Table 4: Clearance to Walls in an Alcove
Description
Clearance
Minimum Width
43½ inches (1105 mm)
Minimum Height
48 inches (1219 mm)
Maximum Depth
24 inches (610 mm)
B
A
Back Wall
S
id
e
W
al
l
C
C
Adjacent Wall
A
dj
ac
en
t W
al
l
14