beautypg.com

Initial installation – Enviro Cara User Manual

Page 16

background image

When planning your installation, it will be necessary to select the proper length of vent pipe for your

particular requirements. It is important to note when passing through a wall, the maximum allowable

wall thickness is 10 inches (25.4 cm); 1½ inches (3.8 cm) clearance to combustibles must be maintained.

Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine

the length of vent pipe required for vertical installations, measure the distance from the appliance flue

outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow

for sufficient vent height above the roof line. For two story applications, a fire stop is required at each

floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the

venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.

Refer to i

nitiaL

i

nstaLLation

- v

ent

c

onfiguration

and

r

estrictor

s

ettings

for venting parameters.

Your total vent pipe length must be within the grid area of Figures 28 and 29. If a 90° elbow is used in

the horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run.
There are three (3) basic types of Direct Vent System installations. The three (3) types of installations are

shown in Figures 24 through 26.

a

PPRoveD

v

ent

P

aRts

:

Table 5: Approved Vent Manufacturers.

Manufacturer

Trade Name

Nominal Sizes

American Metal Products

AmeriVent Direct

4” - 6 5/8”

Security Chimneys International LTD

Secure Vent

4” - 6 5/8”

Selkirk Metalbestos

Direct-Temp

4” - 6 5/8”

Simpson Dura-Vent

Direct Vent GS

4” - 6 5/8”

The Cara fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT

DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT

DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and

vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of

RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner

joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the

particular requirements.
WARNING: Do not mix parts from different vent manufacturers’ systems.
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS

starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use

of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the

Intertek WH listing of the appliance.

Initial Installation

QUALIFIED INSTALLERS ONLY

16