13 TROUBLESHOOTING

13.1

Motor

Problem

Cause

Solution

Blade does not stop within
10 seconds

1.

Motor brushes not
sealed or lightly sticking

2.

Arbor bolt loosened

3.

Other

1.

Inspect, clean and/or
replace brushes

2.

Retighten the arbor bolt

3.

Contact customer
service

Motor does not start

1.

Blown fuse

2.

Worn brush

3.

Other

1.

Use and check the 9A
time-delay fuse or the
circuit breaker

2.

See MAINTENANCE
section

3.

Contact customer
service

Excessive brush spark when
the switch is released

1.

Brush worn

1.

Replace brushes

13.2

Saw operation

Problem

Cause

Solution

Blade hits table

1.

Misalignment

1.

See ASSEMBLY section

Angle of cut not accurate,
cannot adjust mitre

1.

Mitre table locked

2.

Sawdust under table

1.

Push positive stop
locking lever down and
rotate table

2.

Vacuum or blow out
dust

Cutting arm wobbles

1.

Loose pivot points

1.

See ASSEMBLY section

Cutting arm will not fully raise
or blade guard will not fully
close

1.

Part failure

2.

Pivot spring not
replaced properly after
service

3.

Sawdust build-up

1.

Contact customer
service

2.

Contact customer
service

3.

See MAINTENANCE
section

Blade binds, jams, burns
wood

1.

Improper operation

2.

Dull blade

3.

Improper blade size

4.

Warped blade

1.

See OPERATIONS
section

2.

Replace or sharpen
blade

3.

Replace blade

4.

Replace blade

Saw vibrates or shakes

1.

Saw blade not round

2.

Saw blade damaged

3.

Saw blade loose

4.

Saw blade warped

1.

Replace blade

2.

Replace blade

3.

Tighten arbor bolt

4.

Replace blade

14 SERVICE DEPARTMENT

 Damaged switches must be replaced by our after-sales service department.
 If the connecting cable (or mains plug) is damaged, it must be replaced by a particular

connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).