E-85
Use
ful
fe
atu
re
s
Advanced programmings and registrations
Programming functions of PLUs individually
This part explains programming methods of each function of PLUs individually.
Step
Operation
1
Turn the Mode switch to PGM position and select [System
Setting] then press
F
key.
>
▪▪▪▪▪
>F
2
Enter
3
and press
o
key to set the register in the
programming mode.
3o
3
Referring the tables in the proceeding section, enter two-
digit set code you wish to program followed by two 6s. The
“66” is the identification code for individual programming of
departments and PLUs. Then press
o
key.
BB66o
(set code)
4
Enter PLU number you wish to set and press
PLU/
S.DEPT
key.
0005
PLU/
S.DEPT
This example is for setting a program in PLU
0005.
5
Referring the table in the preceding section, enter program
code and press
F
key.
B
▪▪▪▪▪
BF
(Program code)
6
If you wish to set the same program code in the next PLU
number, press
F
key again.
Perform step 5 if you wish to set another program code to
the next PLU number.
To program in another PLU number (not next PLU number),
repeat steps 4 and 5.
F
7
Press
o
key to complete the settings.
o
Example 1: To set PLU 0001 as “Open PLU”.
Press
3o0466o0001
PLU/
S.DEPT
4Fo
Example 2: To set PLU0012 to link item group 12 and dept. 04.
Press
3o1166o0012
PLU/
S.DEPT
0120004Fo