DSP Type parameter

The value of this block's parameter is rewritten whenever the DSP Type or Tone is changed.

Note 1:
These parameters change the DSP name. One character is indicated by each byte.

Note 2:
This value is the DSP algorithm ID, which cannot be changed directly at the user level. Changing the DSP Type
or Tone Number causes the algorithm ID of the original DSP to be copied automatically to this area. See "25.16
DSP Algorithm ID Table".

DSP Type Independent Parameters
The eight DSP user parameters listed below can be set by the control change messages, while the following16
internal parameters that can be set by system exclusive messages only. The range of these parameter values is 0 to
127, regardless of the DSP algorithm. However, the number of parameter types depends on the DSP algorithm,
which means that not all User Parameters and Internal Parameters are necessarily available as a particular DSP's
parameters.
See the "Part VII DSP Parameter List" for details about parameter types and contents.

ParamID Parameter

bit

Value

Default Setting Value (Decimal)

30

DSP Name A (Note1)

20

0~FFFFFFFF

556e7469 MSB is leading character.

31

DSP Name B (Note1)

20

0~FFFFFFFF

746c6564 MSB is leading character.

32r

DSP Algorithm ID (Note2)

07

00~3F

00

0~63

33

DSP Chorus Send

07

00~7F

40

0~127

34

DSP Reverb Send

07

00~7F

40

0~127

ParamID Parameter

bit

Value

Default Setting

Value (Decimal)

38

DSP User Parameter0

07

00-7F

-

0-127

39

DSP User Parameter1

07

00-7F

-

0-127

3A

DSP User Parameter2

07

00-7F

-

0-127

3B

DSP User Parameter3

07

00-7F

-

0-127

3C

DSP User Parameter4

07

00-7F

-

0-127

3D

DSP User Parameter5

07

00-7F

-

0-127

3E

DSP User Parameter6

07

00-7F

-

0-127

3F

DSP User Parameter7

07

00-7F

-

0-127

40

DSP Internal Param00

07

00-7F

-

0-127

41

DSP Internal Param01

07

00-7F

-

0-127

42

DSP Internal Param02

07

00-7F

-

0-127

43

DSP Internal Param03

07

00-7F

-

0-127

44

DSP Internal Param04

07

00-7F

-

0-127

45

DSP Internal Param05

07

00-7F

-

0-127

46

DSP Internal Param06

07

00-7F

-

0-127

47

DSP Internal Param07

07

00-7F

-

0-127

48

DSP Internal Param08

07

00-7F

-

0-127

49

DSP Internal Param09

07

00-7F

-

0-127

4A

DSP Internal Param10

07

00-7F

-

0-127

4B

DSP Internal Param11

07

00-7F

-

0-127

4C

DSP Internal Param12

07

00-7F

-

0-127

4D

DSP Internal Param13

07

00-7F

-

0-127

4E

DSP Internal Param14

07

00-7F

-

0-127

4F

DSP Internal Param15

07

00-7F

-

0-127