beautypg.com

System message, Part iii, 13 active sensing – Casio PX-700 User Manual

Page 22: 14 system exclusive message

background image

22

Part III

System Message

13

Active Sensing

Format

Send
This message is not sent when the Instrument is operated.

Receive
Once this message is received, the Active Sensing mode is entered. If no MIDI message is received for a
specified amount of time, voices being sounded by the Instrument's sound source are released, controller is reset,
and Active Sensing mode is exited.

14

System Exclusive Message

Format

This Instrument can send and receive Universal System Exclusive Messages, as well as PX-110/PX-310/PX-700
System Exclusive Messages that have a format that is unique to the Instrument.

14.1

Universal Realtime System Exclusive Message

Format

14.1.1

Master Volume

Format

Note 1:
The setting value matches the value that is sent and received.

Send
This message is not sent when the Instrument is operated.

Receive
Receipt changes the Master Volume parameter. Note that the Master Volume parameter cannot be changed with an
Instrument operation.

Message Format: FEH

Message Format: F0H....F7H

Message Format: F0H 7FH....F7H

Message Format: F0H 7FH 7FH 04H 01H llH mmH F7H

ll: Value LSB (Note 1)
mm: Value MSB (Note 1)