beautypg.com

Parameter list, Part v, 18 command parameter – Casio PX-700 User Manual

Page 39

background image

39

Part V

Parameter List

These lists show the parameters that can be transferred individually using System Exclusive Messages.

Note 1: Any parameter that has "r" to the right of its Parameter ID number is a read-only parameter that can be
used for obtaining status information only.
A parameter with "w" next to its Parameter ID is a write-only parameter, which is used for commands, etc.

Note 2: Except for the "Setting Value" column, all values in the System Exclusive Format table and the Parameter
Lists are hexadecimal, unless specifically noted otherwise.

Note 3: Receipt of a value outside a specified range causes the value marked "Default" to be used instead.

18

Command Parameter

The parameters defined here mainly execute commands and indicates statuses. Values indicate the pointer to a
command or a status.

18.1

System Parameter List

System Exclusive Format

Field

Value

01

SYSEX

F0

02

MAN

44

03

MOD

11,02

04

dev

00 to 1F, or 7F

05

act

00(IPC), 01(IPR)

06

cat

Command = 0

07

prm

00-7F

08

ilen/dlen 0 / bit size - 1

09

ps

LSB,MSB = 00, 00

10

index

00

11

data

See the Parameter List.

12

sum

None

13

EOX

F7