beautypg.com

E-34, Using the optional optical communication unit – Casio DT-810M50RC User Manual

Page 34

background image

E-34

Using the Optional Optical Communication Unit

1

RS-232C connector

For connection of a PC and uploading/downloading of system data
and file data.

2

RS-422 connectors

For connection of multiple optional Optical Communication Units.

3

AC adaptor jack

For connection of an AC adaptor to supply power.

4

Data Collector detection switch

Detects whether or not the Data Collector is mounted correctly on
the Optical Communication Unit.

5

Charge/Power supply terminal

Supplies power to the Data Collector mounted on the Optical
Communication Unit.

6

System operation indicator

Indicates whether or not the system operation is normal. A system
operation problem is indicated when this indicator does not light up
green shortly after the Data Collector is mounted onto the Optical
Communication Unit.
Off: All Data Collectors mounted on the Optical Communication
Units are unable to communicate, or there is a system problem.
Lit Green: Normal system operation. One or more of the Data
Collectors mounted on the Optical Communication Units are
communicating.

7

Data communication indicator

Indicates the status of data communication operations.
Off:

Not communicating

Flashing Green: Communication in progress
Lit Red:

Optical Communication Unit connection problem

8

Charge indicator

Indicates the charge status of the lithium-ion battery pack.
Off:

Not charging (Data Collector battery compartment
contains alkaline batteries)

Lit Red:

Charging

Lit Green:

Charging complete

Flashing Red:

Battery pack problem

Flashing Green: Charging interrupted because ambient

temperature is outside of allowable range for
charging. Charging will resume when temperature
is back within the allowable range.

9

Power indicator

Indicate whether power is on or off, and if the Data Collector is
mounted.
Off:

Power off

Red:

Power on, Data Collector not mounted

Green: Power on, Data Collector mounted

10 Infrared port

This port provides contact-less infrared communication capabilities
with a Data Collector.

11 Power switch

Turns power on and off.

12 Base

Reverse the position of the base when wall mounting the Optical
Communication Unit.

13 DIP switches

Use these switches to set the operational configuration of the
Optical Communication Unit.

14 Wall mounting tab

Secures the Data Collector when mounting it on a wall.

15 Wall mounting hole

Use this hole to attach the Optical Communication Unit to a hook
on a wall.

This manual is related to the following products: