beautypg.com

Appendix d: programming lan bypass, Appendix d, Programming lan bypass – Lanner FW-8756 User Manual

Page 19

background image

16

Programming LAN Bypass

Appendix D

Network Application Platforms

Appendix D:

Programming LAN Bypass

The bypass function is used to link two independent

Ethernet ports when the system crash or powers off.

This means if your system is equipped with a LAN Bypass

function, a condition in your system will not interrupt your

network traffic. There are typically two communication

status for the bypass function, one is “Normal” and another

is “Bypass”. Lanner provides software for controlling the

LAN Bypass function:
Lanner ‘s Bypass Modules include WDT (Watch Dog Timer)

controller and Bypass switch.
Our Bypass Modules also include a software development

kit that enables system designer to efficiently design

systems to support bypass functionality. Lanner Bypass

Modules with watchdog control have the following

features:

Communication through SMBUS (I2C)

Independent bypass status control for each pair up to

a total of 4 pairs
Lanner Bypass Modules can bypass systems Ethernet

ports on a host system during three instances: Just-on

(Just-on is the brief moment when the internal power

supply turns on and booting process starts), system

off, or upon software request (during run-time).
Software programmable bypass or normal mode

Software programmable timer interval:

- JUST-ON watchdog timer, used during JUST-ON, has

timer setting of 5~1275 seconds of timer interval.
- Run-Time watchdog timer, used during run-time, has

setting of 1~255 seconds of timer interval.

Please refer to the Lanner Bypass Watchdog module-

User Guide in the LAN_Bypass_Watchdog folder for

implementation guidance.
For sample LAN bypass code, see the LAN_Bypass_

Watchdog folder on the Driver and Manual CD.
Fro a description of the physical LAN ports equipped with

this function, refer to Front Panel Features in Chapter 1