beautypg.com

Sw version displays the installed software version – KACO XP10U-H4 User Manual

Page 14

background image

C o n f i g u r a t i o n a n d O p e r a t i o n

Page 14

Operator Instructions blueplanet XP10U H4 / H6 and XP10U H4 / H6 PSD

Menu

level

Display/settings

Action in this menu/meaning

0

1

2

3

1

Date & time

 Set the time and date.

NOTICE: For self-diagnostic purposes, the inverter carries out a daily
restart at midnight. To avoid having a restart occur during feed-in
operation and to always obtain reliable log data, ensure that the time is
correctly set.

0

1

2

3

1

Ethernet

 Assign a unique IP address.

 Assign a subnet mask.

 Assign a gateway.

0

1

2

3

1

Webserver

 Activate or deactivate the integrated webserver.

0

1

2

3

0

“Parameters” menu

 Press the right arrow key or the OK key.

NOTICE: The inverter does not display the “Parameters” menu in the
standard confi guration. To display the menu:

1.

Open the menu.

2. Simultaneously hold down the up and down keys for several

seconds.

0

1

2

3

1

Country

1.

Input the four-character password via the 4-way key. The password
is unit-specifi c.

2. Confi rm the entry with the OK key.

3. Set the desired country setting.

NOTICE: This option infl uences the country-specifi c operating settings of
the inverter. Please consult KACO service for further information.

0

1

2

3

1

Grid type/

guideline

 If available, select the type of grid applicable to the use of the

inverter.

0

1

2

3

1

DC starting volt.

The inverter begins feed-in as soon as this PV voltage is present.

 Set the starting voltage.

0

1

2

3

1

Const. volt. ctrl

Off ers the possibility of deactivating the MPP seek mode in order to
operate the inverter with a constant DC voltage.

 Activate or deactivate MPP seek mode.

 Set value for constant voltage control (200 - 800 V).

NOTICE: The possible input power is reduced at voltages lower than

350 voltage. The input current is limited to 18.6 A per input.

0

1

2

3

0

“Information” menu

 Open the menu: Press the right arrow key or

the OK key.

0

1

2

3

1

Inverter type

Displays the type designation of the inverter.

0

1

2

3

1

SW version

Displays the installed software version.

0

1

2

3

1

Serial number

Displays the serial number of the inverter.

0

1

2

3

1

Display country

Displays the selected country setting.

Optional: Displays the grid type if a grid type has been selected.

0

1

2

3

0

“Vendor” menu

»

The display shows information about the unit manufacturer.

This manual is related to the following products: