Jordan Valve 1051M Series Rotary Actuator User Manual
Page 3

-3-
Loading Connection
1.
Connect the loading pressure piping to the
pressure connection in the top of the
diaphragm casing. Run either 1/4-inch
pipe or 3/8-inch tubing between the 1/4-inch
pressure connection and the instrument.
2.
Keep the length of pipe or tubing as short as
possible to avoid transmission lag in
the control signal. Should a volume
booster or valve positioner be used, ensure that
it is properly connected to the factory.
If a valve positioner is part of the assembly, the
connection will l ikely be made at
the Jordan Valve factory.
3.
When the control valve has been completely
installed and connected, check for correct ac-
tion (air-to-open or air-to-close) according to
the controlling instrument. Ensure proper opera-
tion by checking that the actuator stem
and valve shaft are moving freely in
response to the loading pressure
change on the diaphragm.
Figure 3: 1051M Actuator-Valve Mounting
1051M S
erieS
r
otary
a
ctuator
- Mark 51 Series – Self-Operated Back Pressure Regulator (4 pages)
- Mark 51 Series – Self-Operated Back Pressure Regulator (4 pages)
- Mark 62 Series - Internally Piloted Regulator (5 pages)
- Mark 52 Series – Internally Piloted Regulator (5 pages)
- Mark 64 Series – Differential Regulator (2 pages)
- Mark 56 Series – Air Loaded Back Pressure Regulator (5 pages)
- Mark 57 Series – Externally Piloted Regulator (4 pages)
- Mark 58 Series – Globe Style Back Pressure Regulator (4 pages)
- Mark 508 Series – Tank Blanketing Valve (4 pages)
- Mark 508 Series – Tank Blanketing Valve (3 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (17 pages)
- Mark 5108 Series Back Pressure Regulator (4 pages)
- Mark 6127 Series Pressure Reducing Valves (5 pages)
- Mark 6127 Series Pressure Reducing Valves (4 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (5 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (4 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (4 pages)
- Mark 66 Series – Air Loaded Pressure Regulator (5 pages)
- Mark 67 Series – Piloted Sliding Gate Regulator (5 pages)
- Mark 608 Series – Low-Pressure Gas/Tank Blanketing Regulator (4 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (18 pages)
- Mark 608IS – Tank Blanketing/Low Pressure Gas Regulator (5 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (2 pages)
- Mark 627 Series - Gas Service Regulator (4 pages)
- Mark 630 Series - Gas Service/High Pressure Regulator (5 pages)
- Mark 686 Series – Air Loaded Globe Regulator (4 pages)
- Mark 687 Series - Piloted Regulator with Class VI Shutoff (4 pages)
- Mark 688 Series - Piloted Soft Seat Regulator (11 pages)
- Mark 695 Series - Piloted Tank Blanketing Regulator (9 pages)
- Mark 68HP Series – High Pressure Regulator (2 pages)
- Mark 80 Series – Self Operated Temperature Regulator (7 pages)
- Mark 80 Series – Self Operated Temperature Regulator (2 pages)
- Mark 80 Series – Self Operated Temperature Regulator (5 pages)
- Mark 82 Series – Internal Piloted Temperature Regulator (5 pages)
- Mark 85 Series - Controlled Failure Temperature Regulator (5 pages)
- Mark 86 Series - Ambient Temperature Regulator (2 pages)
- Mark 87 Series - Piloted Temperature Regulator (6 pages)
- Mark 89MX Series- Three-Way Temperature Regulator (4 pages)
- Mark CFR Series Pressure Reducing Supply Реле (3 pages)
- Mark 25 Series – Tempilot Temperature (4 pages)
- Mark 4160 Series Pressure Controllers (11 pages)
- 657M Series Diaphragm Actuator (7 pages)
- 667M Series Diaphragm Actuator (8 pages)