Jordan Valve Mark HPX and HPAX Series Globe & Angle Style Панель управления User Manual
Page 4

-4-
Figure 2: Mark HPX and HPAX Series Packing Arrangements
Replacing Packing
Prior to beginning any maintenance, it is important to
isolate the valve from the line pressure, and to release
all pressure from the valve body. Disconnect all operat-
ing lines to the actuator, including air pressure, electri-
cal power or control signal lines. The process pressure
should be released both upstream and downstream of
the valve. Drain the process fluid from both sides of the
valve.
Employ lock-out procedures to ensure the safety of per-
sonnel and equipment during valve service.
Note: Extreme caution must be used during disas-
sembly. Nicks and scratches will affect the ability to
seal the valve in the future.
1.
Remove the cap screws in the stem connector
and separate the two halves.
2.
Exhaust any actuator pressure and disconnect
the actuator supply line and any leakoff piping.
3.
Remove the actuator from the bonnet (key 6)
by removing the yoke lock nut (key 15) and
then remove the actuator from the bonnet.