beautypg.com

Jordan Valve Mark DBAQ Series Angle Style Control Valve User Manual

Page 2

background image

-2-

4.

Lock-out procedures should be strictly

adhered to while the equipment is being

serviced.

5.

To ensure a good gasket seal, the gasket

should be replaced upon re-assembly

whenever it becomes disturbed by removing

or shifting gasketed parts.

Packing Lubrication

These instructions are for the lubricator or lubricator

isolation valve (Figure 1). If the lubricator or lubricator

isolation valve have been installed, they will be in

place of the pipe plug and are designed for packing

that requires lubrication, including PTFE composition.

Jordan Valve recommends a silicone based lubricant.

Lubricant is not recommended for oxygen services or for

processes that operate in excess of 500

o

F (260

o

C). To

add lubricant to the packing box, turn the capscrew in a

clockwise direction.

For Lubricator/Isolating Valve

1.

Open the isolating valve.

2.

Turn the capscrew in a clockwise direction.

3.

Close the isolating valve.

Packing Leakage

Spring-Loaded PTFE V-Ring Packing

To eliminate leakage, tighten the packing flange nuts

(key 18, figure 7). If leakage cannot be controlled in this

manner, the packing will need to be replaced.

Other Packing

If packing other than Spring-Loaded PTFE V-Ring has

been used, attempt to eliminate the leaking and create

a stem seal by tightening the packing flange nuts to

the minimum recommended torque given in Table 5. If
leakage continues, the packing will need to be replaced.

M

ark

DBaQ S

erieS

a

ngle

S

tyle

C

ontrol

V

alVeS

New Packing

If tightening the appropriate flange nuts does not solve

the leakage problem and the packing is relatively new,

leakage could indicate damage to the packing box wall

or to the stem. Inspect the valve stem plug for a good

surface finish as well as the packing box wall for nicks

and scratches that could compromise the seal.

Hint:

If leakage originates from the outside diameter of

the packing, check the packing box wall for nicks or

scratches. If leakage originates from the inside diameter

of the packing, check the stem for nicks or scratches.

Lubricator

Lubricator/ Isolating Valve

Figure 1: Lubricator and Lubricator Isolating Valve