PP.P5G5.03.Troubleshoot

Page 28

Rev. 06/11/2003

o

l3

Over torque detection function.

A customer programmable current detection. Response
may be selected. A minor fault contact output can be
programmed by using the multi-function outputs.

OL3

Overtorque Det 1

OL4

Overtorque Det 2

N/A

Over torque detection function (2).

A customer programmable current detection. Response
may be selected. A minor fault contact output can be
programmed by using the multi-function outputs.

Possible Cause(s):

Motor is overloaded.

Corrective Action:

Verify the program settings, reduce the load on the motor.

Possible Cause(s):

Motor is overloaded.

Corrective Action:

Verify the program settings, reduce the load on the motor.

Fault Codes

Minor Fault

- Operation continues and the digital operator indication blinks

The fault relay does not activate.