beautypg.com

Fault codes, Major fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 23

background image

PP.P5G5.03.Troubleshoot

Page 23

Rev. 06/11/2003

CPF06

Option Error

Option connection fault.

N/A

CPF20

Option A/D Error

A/D converter fault on the (AI-14B) option board.

N/A

Possible Cause(s):

An option board is not correctly connected to the control board, an option

board that is not made for the 515/G5 inverter is attached to the control board.

Corrective Action:

Remove power to the inverter and connect the option board once more.

Perform a factory initialization , cycle power, replace the option board, replace the control board.

Possible Cause(s):

Defective AI-14B option board, external input is loading down the option

board.

Corrective Action:

Remove all inputs to the option board. Perform a factory initialization ,

cycle power, replace the option board, replace the control board.

Fault Codes

Major Fault

- Motor coasts to a stop, the fault is displayed on the digital

operator, and the fault relay is activated.

505

506

515