Yaskawa F7 Drive Overvoltage Suppression User Manual
Page 5

Date: 09/17/2010, Rev: 09-2010
Page 5 of 9
TM.F7SW.062
4.3 Monitors (U1-XX)
Monitor Num
ber
Modbu
s Add
ress
Monitor Name
Digital Operator
Display
Description
Scaling for Multi-
function Analog
Output
(H4-01/H4-04)
Unit
A
cce
ss
 Le
vel
 *1 
U1-90 0720H
Soft Start Frequency
Reference
Soft Start Freq
Displays the 
frequency reference 
after the soft starter, 
but before the OV 
Regulator PI 
controller output. 
100% =
Fmax (E1-04)
0.01
Hz
Q
U1-91 0721H
Overvoltage Frequency
Reference
OV Reg Total Ref
Displays the 
frequency reference 
after the output of the 
OV Regulator PI 
controller. 
100% =
Fmax (E1-04)
0.01
Hz
Q
U1-92 0722H
Overvoltage
Suppression Regulator
Error Signal
OV Reg Error
Displays the error 
(setpoint - feedback) 
of the OV Regulator 
PI controller. 
100% =
Motor Rated
Torque (Iq)
0.1
%
Q
U1-93 0723H
Overvoltage
Suppression Regulator
Output
OV Reg Output
Displays the output of 
the OV Regulator PI 
controller. 
100% =
Fmax (E1-04)
0.1
%
Q
*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”. V/F and Open Loop Vector only. 
 
4.4 Faults 
Fault Display
Description
Cause
Countermeasures
B-BRK
Belt Break
The drive’s output 
frequency was at the 
maximum output 
frequency (E1-04) for 
more than 30 seconds. 
See section 6.3 for details. 
Fix belt / coupling.
 
4.5 Alarms 
Alarm Display
Description
Cause
Countermeasures
OTDLY
Overtemp Delay
Over-temperature Delay
The drive’s heat sink 
temperature exceeded 
parameter L8-02 
(Overheat Pre-alarm 
Level) and then fell below 
the L8-02 level within the 
P2-01 time. This alarm will 
flash until the P2-01 timer 
has expired. See section 
6.4 for details. 
Decrease the drive heat
sink temperature. Check
the drive’s cooling fans.
Check the sizing of the